dc.contributorUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T13:14:18Z
dc.date.available2014-05-20T13:14:18Z
dc.date.created2014-05-20T13:14:18Z
dc.date.issued2005-06-01
dc.identifierArquivo Brasileiro de Medicina Veterinária e Zootecnia. Universidade Federal de Minas Gerais, Escola de Veterinária, v. 57, n. 3, p. 288-294, 2005.
dc.identifier0102-0935
dc.identifierhttp://hdl.handle.net/11449/1817
dc.identifier10.1590/S0102-09352005000300002
dc.identifierS0102-09352005000300002
dc.identifier2-s2.0-31544454140
dc.identifierS0102-09352005000300002.pdf
dc.description.abstractForam estudadas as características físico-químicas e citológicas do líquido sinovial da bainha tendínea digital de nove eqüinos hígidos. Verificou-se que o líquido é viscoso, amarelo claro, límpido, livre de partículas e que não coagula à temperatura ambiente. Sua concentração média de ácido hialurônico foi 60,20mg/dl, a taxa de glicose, similar à plasmática e sua concentração protéica não ultrapassou 1,74g/dl, com relação média albumina:globulina de 0,94. O número médio de células nucleadas foi de 313 células/µl, com predominância de grandes células mononucleares e linfócitos. Houve correlação significativa (r = - 0,649, P<0,01) entre o aumento da concentração de ácido hialurônico e a diminuição percentual de linfócitos. As mensurações das características pesquisadas no líquido sinovial da bainha tendínea digital de eqüinos são de execução simples e passíveis de implantação na rotina de atendimentos clínico-cirúrgicos.
dc.description.abstractPhysical, biochemical and cytological characteristics of the digital flexor tendon sheath synovial fluid were studied in nine clinically normal horses. It is a viscous, pale yellow, clear fluid, without flocculent material and does not clot at room temperature. Its hyaluronic acid mean concentration was 60.20mg/dL, glucose levels were similar to the plasmatic levels, and its protein concentration was up to 1.74g/dL, with mean albumin:globulin ratio of 0.94. Nucleated cells mean number was 313 cells/µL, with predominating large mononuclear cells and lymphocytes. There was a significant correlation (r= -0.649, P<0.01) between increasing hyaluronic acid concentration and decreasing lymphocyte counts. Equine digital tendon sheath synovial fluids can be easily evaluated, being feasible in clinical and surgical routine, and the information may be useful to the diagnosis, treatment and prognosis of animals with tendon sheath associated lesions.
dc.languagepor
dc.publisherUniversidade Federal de Minas Gerais (UFMG), Escola de Veterinária
dc.relationArquivo Brasileiro de Medicina Veterinária e Zootecnia
dc.relation0.286
dc.relation0,248
dc.rightsAcesso aberto
dc.sourceSciELO
dc.subjectEquine
dc.subjectsynovial fluid
dc.subjectTendon digital sheath
dc.subjectEquino
dc.subjectlíquido sinovial
dc.subjectBainha digital tendinea
dc.titleCaracterísticas físico-químicas e citológicas do líquido sinovial da bainha tendínea digital de eqüinos
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución