dc.creatorSolano Barquero, Melissa
dc.creatorChacón Jiménez, Luz María
dc.creatorBarrantes Jiménez, Kenia
dc.creatorAchí Araya, María Rosario
dc.date.accessioned2018-11-15T21:34:51Z
dc.date.accessioned2019-04-25T14:40:37Z
dc.date.available2018-11-15T21:34:51Z
dc.date.available2019-04-25T14:40:37Z
dc.date.created2018-11-15T21:34:51Z
dc.date.issued2012-12
dc.identifierhttp://revistasinvestigacion.unmsm.edu.pe/index.php/rpb/article/view/1050
dc.identifier1727-9933
dc.identifierhttp://hdl.handle.net/10669/76141
dc.identifier10.15381/rpb.v19i3.1050
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/2373137
dc.description.abstractLos métodos de recuento en placa capa doble y capa simple de agar, para la cuantifcación de colifagos somáticos en aguas, fueron implementados utilizando como base metodologías estándar. Diferentes variables fueron ensayadas, lo cual permitió la precisión en algunos pasos no incluidos en metodologías estándares. De los hallazgos de mayor importancia, se exponen las consecuencias de utilizar un cultivo de Escherichia coli excesivamente concentrado y se describe la obtención de un cultivo en fase logarítmica en solo 4 horas de incubación, ajustando la concentración a una densidad óptica de 0,3 a 600nm (3,1 x 108 UFC/ mL), o a un McFarland 1 (3,0 x108 UFC/ mL). Se determinó que los controles de colifagos deben ser almacenados a -70 °C para reducir su degradación y que se deben evitar cantidades superiores a 20 mL de mezcla de reacción por plato de Petri, para reducir las burbujas que pueden interferir con la lectura de unidades formadoras de placas (UFP). Se demostró que los colifagos de las muestras de agua pueden almacenarse 48 horas a 4 °C sin que sufran degradación y que en las muestras con altas concentraciones de colifagos no se observa UFP porque se da una lisis confluente de la capa bacteriana. No se encontraron diferencias signifcativas en la recuperación de colifagos al utilizar un método u otro, pero dichos métodos deben ser evaluados por medio de controles, antes de aplicarlos directamente en el análisis de muestras de agua.
dc.description.abstractTwo plate count methods, double layer and single layer of agar for quantifcation of somatic coliphages in water, were implemented using standard methodologies. Several variables were tested and provided valuable information that was not included in standard methodologies. The most important fndings are described, such as the effect of using an excessively concentrated culture of E. coli and production of a log phase culture in only 4 hours of incubation, adjusting the concentration to an optical density of 0.3 at 600 nm (3.1 x 108 CFU / mL), or to McFarland 1 (3.0 x 108 CFU / mL). It was determined that coliphages controls must be stored at -70 °C to reduce its degradation. Quantities of reaction mixture exceeding 20 mL per Petri dish must be avoided to prevent interfere with bubbles during the counting of plate forming units (PFU). It was demonstrated that coliphages isolated from water samples can be stored for 48 hours at 4 °C without any degradation, and PFU are not observed in samples with high concentrations of coliphages, because a confluent lysis of the bacterial layer. There was no signifcant difference in the recovery of coliphages using doble layer or single layer methods, but such methods should be evaluated by means of controls, before applying them directly in the analysis of water samples
dc.languagees
dc.sourceRevista Peruana de Biología, vol. 19(3), pp. 335 -340
dc.subjectColifagos somáticos
dc.subjectCapa doble de agar
dc.subjectCapa simple de agar
dc.subjectAguas
dc.subjectIndicadores virales
dc.subjectSomatic coliphages
dc.subjectDouble agar layer
dc.subjectSimple agar layer
dc.subjectWater
dc.subjectInviral dicator
dc.subject628.362 Eliminación de aguas negras efluentes
dc.titleImplementación de dos métodos de recuento en placa para la detección de colifagos somáticos, aportes a las metodologías estándar
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución