dc.contributorSpohr, Ana Maria
dc.date.accessioned2014-07-19T02:02:56Z
dc.date.accessioned2019-04-10T21:33:17Z
dc.date.available2014-07-19T02:02:56Z
dc.date.available2019-04-10T21:33:17Z
dc.date.created2014-07-19T02:02:56Z
dc.date.issued2014
dc.identifierhttp://hdl.handle.net/10923/6722
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/2331515
dc.description.abstractO objetivo do estudo foi avaliar a resistência à fratura de coroas cerâmicas utilizando o sistema CAD-CAM Cerec sobre pilares sólidos. Sessenta réplicas de implante synocta RN e pilar sólido foram incluídos em resina acrílica autopolimerizável, sendo divididas aleatoriamente (n=20 por grupo). Três tipos de cerâmicas foram utilizadas: Mark II (feldspática), IPS Empress CAD (leucita) e IPS e. max CAD (dissilicato de lítio). As coroas foram confeccionadas através do sistema CAD-CAM utilizando o software Cerec versão 4. 1. Após receberam glaze e foram cimentadas com RelyX U200 sob carga de cimentação de 1 Kg. Metade dos corpos de prova de cada cerâmica foi submetida ao teste de resistência à fratura em máquina de ensaio universal EMIC-DL 2000 com velocidade de 1 mm/minuto e, a outra metade, após 1. 000. 000 de ciclos de fadiga mecânica com carga de 100 N. Segundo ANOVA de duas vias, a interação entre material e ciclagem mecânica foi significativa (p=0,0001). De acordo com o teste de Tukey (α=5%) a resistência à fratura, sem ciclagem mecânica e com ciclagem mecânica respectivamente, da cerâmica Mark II (405N/454N) foi estatisticamente menor que as cerâmicas IPS Empress CAD (1169N/1240N) e IPS e. max CAD (1378N/1025N) (p<0,05). As cerâmicas IPS Empress CAD e IPS e. max CAD não diferiram estatisticamente entre si (p>0,05). Não houve diferença estatística na resistência à fratura sem e com ciclagem mecânica para as cerâmicas Mark II e IPS Empress CAD (p>0,05, teste t-student). Para a cerâmica IPS e. max CAD, a resistência à fratura sem ciclagem mecânica foi estatisticamente superior à obtida com ciclagem (p<0,05). As cerâmicas IPS Empress CAD e IPS e. max CAD apresentaram maior resistência à fratura quando comparadas com a cerâmica Mark II. A ciclagem mecânica influenciou negativamente apenas a cerâmica IPS e. max CAD.
dc.description.abstractThe aim of the study was to evaluate the fracture resistance of ceramic crowns using Cerec CAD-CAM system on solid pillars. Sixty replica synocta implant and RN solid abutment were embedded in acrylic resin, being randomly assigned (n=20 per group). Three types of ceramics were used: Mark II (feldspar), IPS Empress CAD (leucite) and IPS e. max CAD (lithium disilicate). The crowns were fabricated by CAD-CAM system using the Cerec software version 4. 1. After receiving glaze and were cemented with RelyX U200 cement under load of 1 Kg Half of the specimens of each ceramic was subjected to endurance EMIC DL-2000 test fracture in a universal testing machine with a speed of 1 mm / minute and the other half after 1,000,000 cycles of mechanical stress with a load of 100 N. According to two-way ANOVA, the interaction between the material and mechanical cycling was significant (p = 0. 0001). According to Tukey test (α = 5%) the fracture toughness without mechanical cycling and mechanical cycling, respectively, of Mark II (405N/454N) was statistically lower than ceramic IPS Empress CAD (1169N/1240N) and IPS e. max CAD (1378N/1025N) (p < 0. 05). The ceramic IPS Empress CAD and IPS e. max CAD not differ statistically (p > 0. 05). There was no statistical difference in the resistance to cyclic loading with and without fracture to the Mark II and IPS Empress CAD (p > 0. 05, Student's t test) ceramics. For ceramic IPS e. max CAD, the fracture resistance without mechanical cycling was statistically superior to that obtained with cycling (p < 0. 05). The ceramic IPS Empress CAD and IPS e. max CAD showed higher fracture resistance compared to ceramic Mark II. The cyclic loading negatively influenced only IPS e. max CAD.
dc.languagePortuguês
dc.publisherPontifícia Universidade Católica do Rio Grande do Sul
dc.publisherPorto Alegre
dc.rightsopenAccess
dc.subjectODONTOLOGIA
dc.subjectRESTAURAÇÃO DENTÁRIA
dc.subjectFRATURAS DENTÁRIAS
dc.subjectCERÂMICA DENTÁRIA
dc.titleAvaliação da resistência à fratura de coroas CAD-CAM sobre pilares sólidos
dc.typeTesis


Este ítem pertenece a la siguiente institución