dc.description.abstractObjetivos: 1) avaliar a resistência de união de palitos de microtração quando afixados nas suas extremidades ou na porção lateral; 2) Avaliar a resistência de união dos palitos modificando a posição na máquina de ensaio permitindo que a porção dentinária seja afixada na haste móvel ou fixa do dispositivo de microtração. Materiais e métodos: Vinte dentes terceiros molares tiveram a face oclusal de esmalte removida até a exposição da dentina. Em seguida, foram restaurados seguindo a metodologia de microtração com sistema adesivo PQ1 e um platô de resina composta Amelogen Plus. Após, foram seccionados em palitos com área de secção 0,64 mm2 e comprimento médio de 8,54 mm. Para cada dente foram selecionados 4 palitos da região central os quais foram divididos nos seguintes grupos: TB – resina composta posicionada no mordente móvel da máquina de ensaio (MM); BT – dentina posicionada no MM; NTB – uso da matriz de imobilização lateral (IL) e resina composta no MM; NBT- uso da IL e resina composta no MM. Após, foi realizado o ensaio de microtração com velocidade de 0,5 mm/min. Resultados: Os valores médios obtidos (MPa) na resistência de união à microtração foram (médias seguidas de mesma letra não apresentam diferença estatística para Tukey (p<0,05)): TB- 26,67 (B); BT- 31,90 (AB); NTB- 37,85 (A); NBT – 34,26 (A).Conclusões: o posicionamento do corpo de prova no mordente móvel (TB ou BT) não influenciou nos resultados de microtração; o uso da imobilização lateral do corpo de prova promoveu o aumento dos valores de resistência à microtração.
dc.description.abstractAims: 1) To evaluate the microtensile bond strength (μMTBS) of the square rod shaped (SRS) specimens when fixed on its ends or in the lateral position; 2) to evaluate the μMTBS of the SRS fixed by dentin or composite resin on the moving attachment (MA) from the universal testing machine (UTM).Materials and methods: Twenty third molars sound and extracted had the occlusal surface removed exposing the dentin. Right after, the teeth were restored with the PQ1 adhesive system and Amelogen Plus doing a 6.0mm height composite resin layer according to the microtensile methods. Then, the specimens were cut in square rods with a bond area of 0.64 mm2. From each tooth were selected four samples of the central area and randomly divided in four groups as follows: TB – composite resin positioned on the mobile attachment (MA) from the UTM; BT – dentin positioned on MA from the UTM; NTB – specimens attached to the notched jig (NJ) with the composite resin fixed on the MA; and NBT- specimens attached to the NJ with dentin fixed on the MA. After, the μMTBS testing was performed with a crosshead speed of 0.5mm/min. Results: The mean values of microtensile bond strength in MPa were (means followed by the same letter did not differ significantly at p<0.05) (Tukey`s test): TB- 26.67 (B); BT- 31.90 (AB); NTB- 37.85 (A); and NBT – 34.26 (A).Conclusions: The sample position (TB or BT) on the MA did not influence the μMTBS; the SRS lateral immobilization (NTB and NBT) applying the NJ increased the μMTBS.
dc.languagept_BR
dc.publisherPontifícia Universidade Católica do Rio Grande do Sul
dc.publisherPorto Alegre
dc.subjectODONTOLOGIA
dc.subjectDENTÍSTICA
dc.subjectDENTINA
dc.subjectRESINAS COMPOSTAS
dc.subjectRESISTÊNCIA DOS MATERIAIS
dc.titleAvaliação da influência do modo de fixação dos corpos de prova no ensaio de microtração na resistência de união à dentina