dc.creatorLozano, Valeria Antonella
dc.creatorMunoz de la Peña, Arsenio
dc.creatorEscandar, Graciela Monica
dc.date.accessioned2016-06-06T21:19:26Z
dc.date.available2016-06-06T21:19:26Z
dc.date.created2016-06-06T21:19:26Z
dc.date.issued2014-11
dc.identifierLozano, Valeria Antonella; Munoz de la Peña, Arsenio; Escandar, Graciela Monica; A second-order fluorimetric approach based on a boron dipyrromethene tetraamide derivative for Hg(II) chemosensing in water and fish samples; Royal Society of Chemistry; Analytical Methods; 6; 21; 11-2014; 8535-8543
dc.identifier1759-9660
dc.identifierhttp://hdl.handle.net/11336/6073
dc.description.abstractA new fluorimetric method is described for the determination of Hg(II), based on the selectivity of a boron dipyrromethene tetraamide derivative (BODIPYTD) towards this ion, in combination with second-order chemometric analysis, to deal with matrix interferents. This is the first time that the selectivity of a mercury chemosensor regarding other metal ions is reinforced with the selectivity offered by second-order calibration, which is able to overcome the potential interference produced by organic constituents of natural or bio-samples. After the BODIPYTD–Hg(II) complex was formed, the excitation–emission fluorescence matrix was recorded and parallel factor analysis (PARAFAC) was applied for data processing. This algorithm achieves the second-order advantage and was able to overcome the problem of the presence of unexpected interferents. This method was applied to the direct determination of Hg(II) ions in environmental waters and fish muscle tissues, with minimal pretreatment steps and without the need for organic solvents. The results were successfully evaluated through a spiking recovery study in both types of real samples, which have constituents displaying fluorescence signals potentially able to interfere in the analysis. The latter fact demonstrates the excellent selectivity of the proposed method. The studied concentration range in water samples was 10–30 ng mL−1, while in fish samples it was 0.12–0.30 μg g−1. The limits of detection for water and fish samples were 2 ng mL−1 and 4 × 10−3 μg g−1, respectively, with relative prediction errors below 5%, and a sample throughput of about 8 samples per hour.
dc.languageeng
dc.publisherRoyal Society of Chemistry
dc.relationinfo:eu-repo/semantics/altIdentifier/url/http://pubs.rsc.org/en/Content/ArticleLanding/2014/AY/C4AY01757A
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1039/C4AY01757A
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectSecond-Order Fluorimetric
dc.subjectMercury Ion
dc.subjectBodipy
dc.subjectWater Fish Samples
dc.titleA second-order fluorimetric approach based on a boron dipyrromethene tetraamide derivative for Hg(II) chemosensing in water and fish samples
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución