dc.creatorEngelke, Wilfried
dc.creatorMüller, Alois
dc.creatorDecco, Oscar Alfredo
dc.creatorRau, María J.
dc.creatorCura, Andrea Cecilia
dc.creatorRuscio, Mara L.
dc.creatorKnösel, Michael
dc.date.accessioned2017-09-12T19:26:59Z
dc.date.accessioned2018-11-06T16:14:42Z
dc.date.available2017-09-12T19:26:59Z
dc.date.available2018-11-06T16:14:42Z
dc.date.created2017-09-12T19:26:59Z
dc.date.issued2013-04
dc.identifierEngelke, Wilfried; Müller, Alois; Decco, Oscar Alfredo; Rau, María J.; Cura, Andrea Cecilia; et al.; Displacement of dental implants in trabecular bone under a static lateral load in fresh bovine bone; Wiley; Clinical Implant Dentistry and Related Research; 15; 2; 4-2013; 160-165
dc.identifier1523-0899
dc.identifierhttp://hdl.handle.net/11336/24081
dc.identifier1708-8208
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1906037
dc.description.abstractAim: The study aims to provide objective data for the displacement of titanium screw implants in trabecular bone specimens. One hundred Semados implants (Bego, Bremen, Germany) were inserted in bovine type IV bone specimens. All implants had a diameter of 3.75 mm; 50 implants had a length of 8.5 mm and 50 implants had a length of 15 mm. Insertion torque was determined at intervals of 10, 20, and 30 Ncm. Implants were loaded horizontally with 10, 20, and 30 N for 2 seconds. An indicator strip was attached to the implant abutment to allow direct observation of implant movement relative to the bone surface. Horizontal displacement was assessed with an accuracy of measurement of 10 µm. Seven implants got lost by visible loosening. Degree of displacement was subject to evaluation with all others. Those implants showed a mean displacement of 59 µm for 10 N (n = 100), 173 µm for 20 N (n = 99), and 211 µm for 30 N (n = 93). The mean displacement of 15-mm implants (16, 37, 51 µm) was significantly lower compared with 8.5-mm implants (103, 311, 396 µm) corresponding to 10, 20, and 30 N as lateral loads. Conclusions: Displacement of screw implants in trabecular bone can be detected and visualized using commercially available endoscopes with a high magnification. A lateral load of 20 N indicates a mean displacement of over 100 µm and therefore results in a critical displacement.
dc.languageeng
dc.publisherWiley
dc.relationinfo:eu-repo/semantics/altIdentifier/url/http://onlinelibrary.wiley.com/doi/10.1111/j.1708-8208.2011.00338.x/abstract
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1111/j.1708-8208.2011.00338.x
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectCONTACT ENDOSCOPY
dc.subjectDISPLACEMENT
dc.subjectIMPLANT LENGHT
dc.subjectINSERTION TORQUE
dc.subjectLATERAL LOADING
dc.subjectPRIMARY STABILITY
dc.titleDisplacement of dental implants in trabecular bone under a static lateral load in fresh bovine bone