dc.creatorPfaffen, Maria Valeria del Valle
dc.creatorFaudone, Sonia Nerina
dc.creatorSperandeo, Norma Rebeca
dc.creatorCuffini, Silvia Lucia
dc.creatorOrtiz, Patricia Ines
dc.date.accessioned2017-09-27T13:54:41Z
dc.date.accessioned2018-11-06T16:02:32Z
dc.date.available2017-09-27T13:54:41Z
dc.date.available2018-11-06T16:02:32Z
dc.date.created2017-09-27T13:54:41Z
dc.date.issued2013-03
dc.identifierPfaffen, Maria Valeria del Valle; Faudone, Sonia Nerina; Sperandeo, Norma Rebeca; Cuffini, Silvia Lucia; Ortiz, Patricia Ines; Determination of Azithromycin by an alternative FIA amperometric method for different pharmaceutical applications; American Chemical Society; Industrial & Engineering Chemical Research; 52; 14; 3-2013; 4973-4977
dc.identifier0888-5885
dc.identifierhttp://hdl.handle.net/11336/25173
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1903849
dc.description.abstractThis work presents a fast and reliable electroanalytical procedure for the quantification of azithromycin (AZ) in different systems that couples flow injection analysis and amperometric detection (FIA-AM). The quantification was performed at a working potential of 1.20 V (vs Ag/AgCl/NaCl (3 M)) in 0.05 M phosphate buffer at a flow rate of 1.0 mL min−1 . Under these conditions a 1.00 × 10−6 −1.50 × 10−5 M linear range, (5.8 ± 0.4) × 104 CAZ (μA M −1 ) sensitivity and 4.44 × 10−7 M limit of detection are obtained. Also, this technique can be used without sample pretreatment and presents good reproducibility. The procedure was applied to the determination of the content of AZ in commercial tablets, to study the intrinsic dissolution rate of compacts of AZ dihydrate, and to determine the AZ release from a AZ hydrogel and carbomer. The method was statistically analyzed and proves to be reliable and robust. However, more remarkable is that FIA-AM technique presents better sensitivity and high sampling rate.
dc.languageeng
dc.publisherAmerican Chemical Society
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1021/ie3027845
dc.relationinfo:eu-repo/semantics/altIdentifier/url/http://pubs.acs.org/doi/abs/10.1021/ie3027845
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectAZITROMICINA
dc.subjectANALISI POR INYECCION EN FLUJO
dc.subjectAMPEROMETRIA
dc.subjectMUESTRAS FARMACEUTICAS
dc.titleDetermination of Azithromycin by an alternative FIA amperometric method for different pharmaceutical applications