dc.creatorGuillen, Daniel
dc.creatorIdarraga Ospina, Gina
dc.creatorMombello, Enrique Esteban
dc.creatorCabral, Sergio
dc.date.accessioned2018-09-27T21:00:05Z
dc.date.accessioned2018-11-06T15:12:32Z
dc.date.available2018-09-27T21:00:05Z
dc.date.available2018-11-06T15:12:32Z
dc.date.created2018-09-27T21:00:05Z
dc.date.issued2016-07
dc.identifierGuillen, Daniel; Idarraga Ospina, Gina; Mombello, Enrique Esteban; Cabral, Sergio; Partial discharges location in transformer winding using wavelets and Kullback-Leibler divergence; Elsevier Science Sa; Electric Power Systems Research; 136; 7-2016; 398-405
dc.identifier0378-7796
dc.identifierhttp://hdl.handle.net/11336/61135
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1894703
dc.description.abstractA new algorithm to partial discharges (PD) location in transformer windings by means of the discrete wavelets transform (DWT) and the Kullback-Leibler (KL) divergence is presented. When the insulation system of transformers has considerable damage, high levels of PD appear. A PD analysis will help to prevent and to avoid catastrophic faults in the transformer insulation system, and is also useful to quantify the damage level into it. However, it is a complex task, because PD signals have a small magnitude and are presented during some microseconds. In this paper, a lumped parameter model RLC is used to model the transformer winding and to obtain PD reference signals. The DWT is used to process those signals. PD location is finally estimated by means of the minimum entropy concept that minimizes the Kullback-Leibler (KL) divergence between PD signals (test and reference signals). Different time durations and amplitudes to the PD signals were considered. The results of computer simulation confirm the accuracy of the proposed algorithm, with an error less than 5%. Also, the algorithm is validated in a distribution transformer winding.
dc.languageeng
dc.publisherElsevier Science Sa
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.epsr.2016.03.020
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0378779616300670
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectDISCRETE WAVELET TRANSFORM (DWT)
dc.subjectKULLBACK-LEIBLER (KL) DIVERGENCE
dc.subjectPARTIAL DISCHARGES
dc.subjectPD LOCATION
dc.subjectTRANSFORMER WINDINGS
dc.titlePartial discharges location in transformer winding using wavelets and Kullback-Leibler divergence
dc.typeArtículos de revistas
dc.typeArtículos de revistas
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución