dc.creatorMarozzi, Carlos A.
dc.creatorGennero, Maria Rosa
dc.creatorChialvo, Abel Cesar
dc.date.accessioned2016-07-07T20:11:05Z
dc.date.accessioned2018-11-06T14:40:34Z
dc.date.available2016-07-07T20:11:05Z
dc.date.available2018-11-06T14:40:34Z
dc.date.created2016-07-07T20:11:05Z
dc.date.issued2013-09
dc.identifierMarozzi, Carlos A.; Gennero, Maria Rosa; Chialvo, Abel Cesar; Analysis of the applicability of short time chronoamperometry for the kinetic study of the hydrogen oxidation reaction; Elsevier; Electrochimica Acta; 112; 9-2013; 68-73
dc.identifier0013-4686
dc.identifierhttp://hdl.handle.net/11336/6391
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1888888
dc.description.abstractThis work analyses the applicability of the chronoamperometric method for the evaluation of the kinetic parameters of the hydrogen oxidation reaction. It consists in the application of an overpotential step and the subsequent plot of the current density response against the square root of time. The extrapolation of the resulting straight line at short times is assigned to the kinetic current density at such overpotential. Then, from the polarization curve, the parameters exchange current density and Tafel slope are evaluated. This method is only strictly valid for simple reactions without adsorbed intermediates. Therefore, a complete analysis that takes into account all the phenomena involved, including the effect of the pseudocapacitive current due to the adsorbed hydrogen, is carried out. The results obtained confirm the inapplicability of the chronoamperometric method for the kinetic study of the hydrogen oxidation reaction.
dc.languageeng
dc.publisherElsevier
dc.relationinfo:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S0013468613015971
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.electacta.2013.08.068
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/10.1016/j.electacta.2013.08.068
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectCHRONOAMPEROMETRY
dc.subjectHYDROGEN OXIDATION REACTION
dc.subjectKINETIC PARAMETERS
dc.subjectPSEUDOCAPACITIVE CURRENT
dc.titleAnalysis of the applicability of short time chronoamperometry for the kinetic study of the hydrogen oxidation reaction
dc.typeArtículos de revistas
dc.typeArtículos de revistas
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución