dc.identifierBerli, Marcelo Eduardo; Campana, Diego Martín; Ubal, Sebastian; Di Paolo, José; ¿Cómo afecta la viscoelasticidad de los polímeros a la lubricación de las prótesis de rodilla? Predicciones desde un modelo de prótesis autolubricada; Universidad Central de Venezuela; Revista de la Facultad de Ingeniería de la Universidad Central de Venezuela; 28; 4; 10-2013; 15-24
dc.identifier0798-4065
dc.identifierhttp://hdl.handle.net/11336/1958
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1887110
dc.description.abstractEl desgaste del polietileno de las prótesis de rodilla, es reconocido como el principal problema limitante en la duración de estos implantes. La dificultad de realizar mediciones in vivo de las variables que influyen sobre el desgaste en la zona de contacto, motivó el estudio numérico de modelos teóricos. Trabajos anteriores se centraron en el estudio de las variables hidrodinámcas mostrando una optimización en la lubricación de la junta ante la presencia de un material elástico de baja rigidez. No obstante, los materiales poliméricos actualmente utilizados o en etapa de investigación son viscoelásticos, pudiendo esta característica modificar las predicciones previas. En este trabajo se presenta un modelo de lubricación de una prótesis de rodilla compuesta por un componente femoral metálico y un componente tibial conteniendo en su superficie un material viscoelástico lineal. Los resultados muestran que los espesores lubricantes sufren modificaciones de considerable magnitud al comparar los resultados de modelos elásticos previos con el propuesto en este trabajo. Luego, se extraen conclusiones dirigidas a la optimización de la lubricación del implante a través de una hipotética capacidad de exudación del material adherido al componente tibial.
dc.description.abstractPolyethylene wear of the tibial component is recognized as the main problem limiting the duration of these implants. The difficulty of in vivo measurements of the variables that influence wear, has motivated the numerical study of theoretical models. Previous works focused on studying the lubricant film thickness, the pressure field and friction coefficient in the contact zone of the prosthesis, showing an optimization of the joint lubrication with the presence of a low rigidity elastic material. However, polymeric materials currently used or under investigation are viscoelastic. This feature can modify previous predictions and consequently the design proposals. This paper presents a model of lubrication of a knee prosthesis comprising a metal femoral component and a tibial component containing a linear viscoelastic material on the articular surface. The results obtained by a numerical technique based on finite elements, show that film thicknesses are considerably affected by viscoelasticity when comparing the results of this work with previous elastic models predictions. Then, conclusions are drawn directed to the optimization of lubrication through the material properties of the polymer and a exudation capacity of a hypothetical material adhered to the tibial component.
dc.languagespa
dc.publisherUniversidad Central de Venezuela
dc.relationinfo:eu-repo/semantics/altIdentifier/url/http://www.scielo.org.ve/pdf/rfiucv/v28n4/art03.pdf
dc.relationinfo:eu-repo/semantics/altIdentifier/url/http://saber.ucv.ve/ojs/index.php/rev_fiucv/article/view/7183/6909
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectPrótesis de rodilla
dc.subjectViscoelasticidad
dc.subjectElementos finitos
dc.subjectDesgaste
dc.subjectPolímero poroso
dc.title¿Cómo afecta la viscoelasticidad de los polímeros a la lubricación de las prótesis de rodilla? Predicciones desde un modelo de prótesis autolubricada
dc.typeArtículos de revistas
dc.typeArtículos de revistas
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución