dc.creatorNúñez, Rubén Orlando
dc.creatorOggier, German Gustavo
dc.creatorBotterón, Fernando
dc.creatorGarcia, Guillermo
dc.date.accessioned2018-04-26T20:37:50Z
dc.date.accessioned2018-11-06T14:27:57Z
dc.date.available2018-04-26T20:37:50Z
dc.date.available2018-11-06T14:27:57Z
dc.date.created2018-04-26T20:37:50Z
dc.date.issued2016-07
dc.identifierNúñez, Rubén Orlando; Oggier, German Gustavo; Botterón, Fernando; Garcia, Guillermo; Analysis of the Transformer Influence on a Three-Phase Dual Active Bridge DC-DC Converter; Institute of Electrical and Electronics Engineers; IEEE Latin America Transactions; 14; 7; 7-2016; 3048-3055
dc.identifier1548-0992
dc.identifierhttp://hdl.handle.net/11336/43616
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1886654
dc.description.abstractIn this work, the impact of the high-frequency transformer on the three-phase dual active bridge DC-to-DC converter operation is investigated, using four transformers with different connections: star-star, delta-delta, star-delta and delta-star. The main objective is to evaluate what is the transformer connection that allows the converter to be operated with high efficiency for different voltage conversion ratios and output power. The apparent power requirements of the high frequency transformers and the power semiconductors stress are evaluated, which allows obtaining the soft switching operating range for each transformer connection. The results of the analysis allow to select the most suitable transformer connection for each application.
dc.languageeng
dc.publisherInstitute of Electrical and Electronics Engineers
dc.relationinfo:eu-repo/semantics/altIdentifier/url/http://ieeexplore.ieee.org/document/7587601/
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1109/TLA.2016.7587601
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectDC-DC CONVERTERS
dc.subjectTHREE-PHASE DUAL ACTIVE BRIDGE CONVERTER: PHASE-SHIFT CONTROL
dc.subjectTHREE-PHASE TRANSFORMER
dc.titleAnalysis of the Transformer Influence on a Three-Phase Dual Active Bridge DC-DC Converter
dc.typeArtículos de revistas
dc.typeArtículos de revistas
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución