dc.creatorRamírez, M.
dc.creatorMartínez Clemente, Nahuel Facundo
dc.creatorMarcazzo, Salvador Julian
dc.creatorMolina, Pablo Fernando
dc.creatorFeld, D.
dc.creatorSantiago, Martin Alejo
dc.date.accessioned2018-09-04T22:11:34Z
dc.date.accessioned2018-11-06T13:58:14Z
dc.date.available2018-09-04T22:11:34Z
dc.date.available2018-11-06T13:58:14Z
dc.date.created2018-09-04T22:11:34Z
dc.date.issued2016-10
dc.identifierRamírez, M.; Martínez Clemente, Nahuel Facundo; Marcazzo, Salvador Julian; Molina, Pablo Fernando; Feld, D.; et al.; Performance of ZnSe(Te) as fiberoptic dosimetry detector; Pergamon-Elsevier Science Ltd; Applied Radiation and Isotopes; 116; 10-2016; 1-7
dc.identifier0969-8043
dc.identifierhttp://hdl.handle.net/11336/58323
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1881260
dc.description.abstractFiberoptic dosimetry (FOD) is an experimental technique suitable for in-vivo, real time dosimetry in radiotherapy treatments. FOD relies on using a small scintillator coupled to one end of a long optical fiber. The scintillator is placed at the point where the dose rate is to be determined whereas a light detector at the other end of the fiber measures the intensity of the radioluminescence emitted by the scintillator. One of the problems hampering the straightforward application of this technique in clinics is the presence of Cherenkov radiation generated in the fiber by the ionizing radiation, which adds to the scintillating light and introduces a bias in the dose measurement. Since Cherenkov radiation is more important in short wavelength range of the visible spectrum, using red-emitting scintillators as FOD detectors permits to reduce the Cherenkov contribution by using optical filters. In this work, the performance of red-emitting tellurium-doped zinc selenide crystal as FOD detector is evaluated and compared to the response of an ion-chamber.
dc.languageeng
dc.publisherPergamon-Elsevier Science Ltd
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1016/j.apradiso.2016.07.007
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0969804316303645
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectFIBER OPTIC DOSIMETRY
dc.subjectREAL TIME DOSIMETRY
dc.subjectTELLURIUM DOPED ZINC SELENIDE
dc.subjectZNSE(TE)
dc.titlePerformance of ZnSe(Te) as fiberoptic dosimetry detector