dc.identifierDi Maio, Angel Antonio; Villagrán Zaccardi, Yury Andrés; Electrical resistivity measurement of unsaturated concrete samples; ICE Publishing; Magazine Of Concrete Research; 66; 10; 4-2014; 484-491
dc.identifier0024-9831
dc.identifierhttp://hdl.handle.net/11336/31414
dc.identifier1751-763X
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1877672
dc.description.abstractElectrical conduction in concrete primarily occurs via the liquid in pores. Since concrete resistivity is sensitive to moisture content, resistivity can be used to infer other moisture-dependent concrete properties. However, quantitative assessment of the relationship between concrete resistivity and the pore liquid content can be a difficult task due to contact issues between electrodes and the surface of unsaturated concrete. Resistivity is usually measured using wet sponges to assess contact with a concrete surface. This is a very effective procedure for saturated concrete but implies minor alterations in the condition of unsaturated concrete. This paper deals with a contact method to measure the resistivity of unsaturated concrete samples. Resistivity measurements dispensing with wet contacts are performed on thin samples of conventional concrete. A dry contact is achieved by means of painted electrodes on the concrete surface. Dry and wet contact methods are compared when applied to saturated concrete, and resistivity values of unsaturated concrete are related to concrete moisture content and the relative humidity of the surrounding environment. As a result, resistivity is related to the volumetric fraction of conducting water in pores and its hygroscopic equilibrium with the surrounding environment.
dc.languageeng
dc.publisherICE Publishing
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1680/macr.13.00207
dc.relationinfo:eu-repo/semantics/altIdentifier/url/http://www.icevirtuallibrary.com/doi/10.1680/macr.13.00207
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectRESISTIVITY
dc.subjectUNSATURATED CONCRETE
dc.subjectPORE LIQUID
dc.titleElectrical resistivity measurement of unsaturated concrete samples
dc.typeArtículos de revistas
dc.typeArtículos de revistas
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución