dc.creator | Repetto, Esteban Martín | |
dc.creator | Gonzalez, Diego Javier | |
dc.creator | Jacobsen, Dario | |
dc.creator | Smithuis, Fernando | |
dc.creator | Jamardo, Juan | |
dc.creator | Cano, Mariel | |
dc.creator | Aranda, Claudio | |
dc.creator | Oneto, Adriana | |
dc.creator | Berg, Gabriela Alicia | |
dc.creator | Fabre, Bibiana | |
dc.date.accessioned | 2017-07-12T23:20:25Z | |
dc.date.accessioned | 2018-11-06T13:34:15Z | |
dc.date.available | 2017-07-12T23:20:25Z | |
dc.date.available | 2018-11-06T13:34:15Z | |
dc.date.created | 2017-07-12T23:20:25Z | |
dc.date.issued | 2017-03 | |
dc.identifier | Repetto, Esteban Martín; Gonzalez, Diego Javier; Jacobsen, Dario; Smithuis, Fernando; Jamardo, Juan; et al.; Evaluation of an automated chemiluminescent immunoassay for salivary cortisol measurement. Utility in the diagnosis of Cushing's syndrome; De Gruyter; Clinical Chemistry and Laboratory Medicine; 55; 3; 3-2017; 65-68 | |
dc.identifier | 1434-6621 | |
dc.identifier | http://hdl.handle.net/11336/20322 | |
dc.identifier | CONICET Digital | |
dc.identifier | CONICET | |
dc.identifier.uri | http://repositorioslatinoamericanos.uchile.cl/handle/2250/1876960 | |
dc.description.abstract | The aim of the current study was to validate an automated chemiluminescent immunoassay for cortisol quantification in saliva and to determine the cut-off level for Cushing´s Syndrome diagnosis in an adult population. The salivary cortisol levels from healthy individuals and patients previously diagnosed with Cushing´s Syndrome were measured with Siemens Immulite 2000 ® automatic chemiluminescent enzyme-immunoassay analyser with a brief modification. The limit of quantification was 3,4 nmol/L. The assay also demonstrated a high level of accuracy, as determined by linearity under dilution and recovery tests. Using this methodology, levels higher than 5.7 nmol/L is indicative of Cushing´s Syndrome with a diagnostic sensitivity and specificity of 90,5% and 97.4% respectively. The assay validated in the present study could be used in the clinical laboratories for the evaluation of cortisol levels in patients in which Cushing´s Syndrome is suspected. | |
dc.language | eng | |
dc.publisher | De Gruyter | |
dc.relation | info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1515/cclm-2016-0585 | |
dc.relation | info:eu-repo/semantics/altIdentifier/url/https://www.degruyter.com/view/j/cclm.2017.55.issue-3/cclm-2016-0585/cclm-2016-0585.xml | |
dc.rights | https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ | |
dc.rights | info:eu-repo/semantics/restrictedAccess | |
dc.subject | CHEMILUMINESCENCE | |
dc.subject | CORTISOL | |
dc.subject | CUSHING'S SYNDROME | |
dc.subject | SALIVA | |
dc.title | Evaluation of an automated chemiluminescent immunoassay for salivary cortisol measurement. Utility in the diagnosis of Cushing's syndrome | |
dc.type | Artículos de revistas | |
dc.type | Artículos de revistas | |
dc.type | Artículos de revistas | |