dc.creator | Bortolin, Lucas | |
dc.creator | Craiem, Damian | |
dc.creator | Gorgolino, Jorge | |
dc.creator | Santoriello, Gerardo Luis | |
dc.creator | Lutenberg, Ariel | |
dc.creator | Graf Caride, Diego Sebastián | |
dc.date.accessioned | 2017-08-23T20:57:37Z | |
dc.date.accessioned | 2018-11-06T13:31:35Z | |
dc.date.available | 2017-08-23T20:57:37Z | |
dc.date.available | 2018-11-06T13:31:35Z | |
dc.date.created | 2017-08-23T20:57:37Z | |
dc.date.issued | 2013-02 | |
dc.identifier | Bortolin, Lucas; Craiem, Damian; Gorgolino, Jorge; Santoriello, Gerardo Luis; Lutenberg, Ariel; et al.; Design of a portable system for continuous recording of arterial parameters during 24h; Institute of Electrical and Electronics Engineers; IEEE Latin America Transactions; 11; 1; 2-2013; 126-129 | |
dc.identifier | 1548-0992 | |
dc.identifier | http://hdl.handle.net/11336/22904 | |
dc.identifier | CONICET Digital | |
dc.identifier | CONICET | |
dc.identifier.uri | http://repositorioslatinoamericanos.uchile.cl/handle/2250/1876344 | |
dc.description.abstract | The simultaneous measurement of pressure and diameter in a central artery during 24 hours could bring new information about the variability of the arterial mechanical properties. In order to perform these measurements in an animal, it is essential to count with a device that could acquire the signals from the sensors with a proper preconditioning circuit and then transfer them wirelessly to be stored and processed remotely. In this paper we present the prototype of a new portable and autonomous device, capable of being hosted on the animal's back. Preliminary results obtained from a pilot experience in a sheep using the prototype are detailed and limitations are discussed. | |
dc.language | spa | |
dc.publisher | Institute of Electrical and Electronics Engineers | |
dc.relation | info:eu-repo/semantics/altIdentifier/url/http://ieeexplore.ieee.org/document/6502790/ | |
dc.relation | info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1109/TLA.2013.6502790 | |
dc.rights | https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ | |
dc.rights | info:eu-repo/semantics/restrictedAccess | |
dc.subject | Arterial stiffness | |
dc.subject | 24 hour elasticity variability | |
dc.subject | ARM Cortex | |
dc.subject | Conscious animal instrumentation | |
dc.subject | Pressure measurement | |
dc.subject | Biomedical equipment | |
dc.subject | Biomedical measurement | |
dc.subject | Blood vessels | |
dc.subject | Diameter measurement | |
dc.subject | Portable instruments | |
dc.title | Design of a portable system for continuous recording of arterial parameters during 24h | |
dc.type | Artículos de revistas | |
dc.type | Artículos de revistas | |
dc.type | Artículos de revistas | |