dc.creatorGuerrero, Federico Nicolás
dc.creatorSpinelli, Enrique Mario
dc.date.accessioned2018-10-12T15:03:53Z
dc.date.accessioned2018-11-06T12:45:02Z
dc.date.available2018-10-12T15:03:53Z
dc.date.available2018-11-06T12:45:02Z
dc.date.created2018-10-12T15:03:53Z
dc.date.issued2017-10
dc.identifierGuerrero, Federico Nicolás; Spinelli, Enrique Mario; A simple encoding method for Sigma-Delta ADC based biopotential acquisition systems; Taylor & Francis; Journal Of Medical Engineering And Technology; 41; 7; 10-2017; 546-552
dc.identifier0309-1902
dc.identifierhttp://hdl.handle.net/11336/62304
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1869781
dc.description.abstractSigma Delta analogue-to-digital converters allow acquiring the full dynamic range of biomedical signals at the electrodes, resulting in less complex hardware and increased measurement robustness. However, the increased data size per sample (typically 24 bits) demands the transmission of extremely large volumes of data across the isolation barrier, thus increasing power consumption on the patient side. This problem is accentuated when a large number of channels is used as in current 128–256 electrodes biopotential acquisition systems, that usually opt for an optic fibre link to the computer. An analogous problem occurs for simpler low-power acquisition platforms that transmit data through a wireless link to a computing platform. In this paper, a low-complexity encoding method is presented to decrease sample data size without losses, while preserving the full DC-coupled signal. The method achieved a 2.3 average compression ratio evaluated over an ECG and EMG signal bank acquired with equipment based on Sigma-Delta converters. It demands a very low processing load: a C language implementation is presented that resulted in an 110 clock cycles average execution on an 8-bit microcontroller.
dc.languageeng
dc.publisherTaylor & Francis
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/https://dx.doi.org/10.1080/03091902.2017.1366562
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://www.tandfonline.com/doi/full/10.1080/03091902.2017.1366562
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectBIOMEDICAL SIGNAL
dc.subjectBIOPOTENTIAL
dc.subjectDYNAMIC RANGE
dc.subjectECG
dc.subjectEMG
dc.subjectENCODING
dc.subjectLOSSLESS COMPRESSION
dc.subjectSIGMA DELTA CONVERTER
dc.titleA simple encoding method for Sigma-Delta ADC based biopotential acquisition systems
dc.typeArtículos de revistas
dc.typeArtículos de revistas
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución