dc.creatorArgañaraz, Juan Pablo
dc.creatorLandi, Marcos Alejandro
dc.creatorBravo, Sandra Josefina
dc.creatorGavier Pizarro, Gregorio
dc.creatorScavuzzo, Carlos Marcelo
dc.creatorBellis, Laura Marisa
dc.date.accessioned2018-10-16T14:26:42Z
dc.date.available2018-10-16T14:26:42Z
dc.date.created2018-10-16T14:26:42Z
dc.date.issued2016-12
dc.identifierArgañaraz, Juan Pablo; Landi, Marcos Alejandro; Bravo, Sandra Josefina; Gavier Pizarro, Gregorio; Scavuzzo, Carlos Marcelo; et al.; Estimation of live fuel moisture content from MODIS Images for fire danger assessment in southern Gran Chaco; Institute of Electrical and Electronics Engineers; IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing; 9; 12; 12-2016; 5339-5349
dc.identifier1939-1404
dc.identifierhttp://hdl.handle.net/11336/62387
dc.identifierCONICET Digital
dc.identifierCONICET
dc.description.abstractMoisture content of live fuels (LFMC) is one of the main factors determining fuel flammability and, therefore, a key indicator of fire danger. In this study, we modeled the relationship between spectral indices derived from satellite imagery and field estimations of LFMC in the Chaco Serrano subregion; then, we analyzed the relationship between fire danger estimations based on LFMC calculations and fire activity. Empirical LFMC models fitted for grasslands, Chaco Serrano forests, and glossy privet forests may be considered very accurate R2 > 0.80, whereas the model corresponding to shrublands still needs to be improved (R2 = 0.57). Monthly maps of fire danger reflected the occurrence of fires consistently during years of both high and low fire activity. Most fires occurred mainly in areas with high or extreme fire danger, demonstrating a clear relationship between LFMC and fire activity in the Chaco Serrano subregion. Our LFMC models may be useful to assess the spatiotemporal distribution of fire danger in the Chaco Serrano subregion using remote sensing data. The associated fire danger maps represent a valuable tool for improving decision making processes to organize early warning and fire suppression activities.
dc.languageeng
dc.publisherInstitute of Electrical and Electronics Engineers
dc.relationinfo:eu-repo/semantics/altIdentifier/url/http://ieeexplore.ieee.org/document/7503072/
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1109/JSTARS.2016.2575366
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.5/ar/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectFires
dc.subjectModeling
dc.subjectMoisture Measurement
dc.subjectPrediction Methods
dc.subjectRisk Analysis
dc.titleEstimation of live fuel moisture content from MODIS Images for fire danger assessment in southern Gran Chaco
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución