dc.creatorSchneider Teixeira, Aline
dc.creatorGonzalez Benito, M. Elena
dc.creatorMolina García, Antonio D.
dc.date.accessioned2016-12-29T21:23:06Z
dc.date.accessioned2018-11-06T12:07:47Z
dc.date.available2016-12-29T21:23:06Z
dc.date.available2018-11-06T12:07:47Z
dc.date.created2016-12-29T21:23:06Z
dc.date.issued2014-08
dc.identifierSchneider Teixeira, Aline; Gonzalez Benito, M. Elena; Molina García, Antonio D.; Measurement of cooling and warming rates in vitrification-based plant cryopreservation protocols; American Chemical Society; Biotechnology Progress; 30; 5; 8-2014; 1177–1184
dc.identifier8756-7938
dc.identifierhttp://hdl.handle.net/11336/10655
dc.identifier1520-6033
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1863417
dc.description.abstractCryopreservation protocols include the use of additives and pre-treatments aimed to reduce the probability of ice nucleation at all temperatures, mainly through micro-viscosity increase. Still, there is a risk of ice formation in the temperature region comprised between the equilibrium freezing (Tf) and the glass transition (TG) temperatures. Consequently, fast cooling and warming, especially in this region, is a must to avoid ice-derived damage. Vitrification and droplet-vitrification techniques, frequently used cryopreservation protocols based in fast cooling, were studied, alongside with the corresponding warming procedures. A very fast data acquisition system, able to read very low temperatures, down to that of liquid nitrogen, was employed. Cooling rates, measured between -20 and -120 ºC, ranged from ca. 5 ºC s-1 to 400 ºC s-1, while warming rates spanned from ca. 2 ºC s-1 to 280 ºC s-1, for the different protocols and conditions studied. A wider measuring window (0 ºC to -150 ºC) produced lower rates for all cases. The cooling and warming rates were also related to the survival observed after the different procedures. Those protocols with the faster rates yielded the highest survival percentages.
dc.languageeng
dc.publisherAmerican Chemical Society
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1002/btpr.1938
dc.relationinfo:eu-repo/semantics/altIdentifier/url/http://onlinelibrary.wiley.com/doi/10.1002/btpr.1938/abstract
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCooling
dc.subjectWarming
dc.subjectRates
dc.subjectVitrification
dc.subjectDroplet-vitrification
dc.subjectPlant
dc.titleMeasurement of cooling and warming rates in vitrification-based plant cryopreservation protocols
dc.typeArtículos de revistas
dc.typeArtículos de revistas
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución