dc.creatorCarrera Baquero, Sebastián Eduardo
dc.creatorSantiago, Liliana Gabriela
dc.creatorVega, Mabel del Carmen
dc.date.accessioned2018-09-21T18:30:35Z
dc.date.accessioned2018-11-06T12:02:01Z
dc.date.available2018-09-21T18:30:35Z
dc.date.available2018-11-06T12:02:01Z
dc.date.created2018-09-21T18:30:35Z
dc.date.issued2016-11
dc.identifierCarrera Baquero, Sebastián Eduardo; Santiago, Liliana Gabriela; Vega, Mabel del Carmen; Spectrophotometric determination of dithizone-mercury complex by solid phase microextraction in micropipette tip syringe packed with activated carbon xerogel; Elsevier Science; Microchemical Journal; 129; 11-2016; 133-136
dc.identifier0026-265X
dc.identifierhttp://hdl.handle.net/11336/60596
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1862486
dc.description.abstractA new simple miniaturized solid phase microextraction system in a syringe was developed for mercury (Hg) preconcentration of in water samples based on the adsorption of its dithizone complex on a microcolumn. The syringe system contains a micropipette tip packed with activated carbon xerogel. The influence of acidity, eluting agents, amount of adsorbent, complex stability and interfering ions was studied in detail. The complex retained on activated carbon xerogel in the micropipette tip-syringe system could be eluted using ethanol and the concentration was determined by visible spectrophotometry.The method showed good linearity in the range of 30-280 μg L-1, with a limit of detection of 7.6 μg L-1. The relative standard deviation (RSD%) for six replicate measurements of 280 μg L-1 of Hg2+ ion was 1.36%.The proposed method was successfully applied to quantitative determination of Hg2+ in ground water and mineral water with satisfactory results.
dc.languageeng
dc.publisherElsevier Science
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.microc.2016.04.013
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0026265X1630039X
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectACTIVATED CARBON XEROGEL
dc.subjectDITHIZONE
dc.subjectMERCURY
dc.subjectSOLID PHASE MICROEXTRACTION
dc.subjectVISIBLE SPECTROPHOTOMETRY
dc.titleSpectrophotometric determination of dithizone-mercury complex by solid phase microextraction in micropipette tip syringe packed with activated carbon xerogel
dc.typeArtículos de revistas
dc.typeArtículos de revistas
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución