dc.creatorAntoszczuk, Pablo Daniel
dc.creatorGarcia Retegui, Rogelio Adrian
dc.creatorUicich, Gustavo Cesar
dc.date.accessioned2018-10-16T20:08:03Z
dc.date.accessioned2018-11-06T11:43:11Z
dc.date.available2018-10-16T20:08:03Z
dc.date.available2018-11-06T11:43:11Z
dc.date.created2018-10-16T20:08:03Z
dc.date.issued2016-12
dc.identifierAntoszczuk, Pablo Daniel; Garcia Retegui, Rogelio Adrian; Uicich, Gustavo Cesar; Interleaved Boundary Conduction Mode Versus Continous Conduction Mode Magnetic Volume Comparison in Power Converters; Institute of Electrical and Electronics Engineers; IEEE Transactions on Power Electronics; 31; 12; 12-2016; 8037-8041
dc.identifier0885-8993
dc.identifierhttp://hdl.handle.net/11336/62487
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1858422
dc.description.abstractPower converters operating in boundary conduction mode (BCM) can benefit from an efficiency increase compared to continuous conduction mode (CCM) based on the soft-switching transitions at turn-on and/or turn-off. However, for a given average inductor current, the RMS current in BCM converters becomes larger than in CCM converters, leading to an increase in conduction losses. Interleaving smaller BCM power converters overcome this drawback by reducing the total ripple current amplitude at the expense of an increase in complexity and in magnetic parts count. Nevertheless, as the magnetic devices are among the largest components in power converters, it is convenient to find the design conditions under which BCM or CCM could yield the smaller net volume. This paper proposes a method to estimate the volume ratio for magnetic parts, between single-phase CCM and multiple interleaved BCM power converters as a function of the number of phases, inductor loss, and switching frequency. The results obtained can be applied to boost, forward, and flyback dc-to-dc topologies.
dc.languageeng
dc.publisherInstitute of Electrical and Electronics Engineers
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1109/TPEL.2016.2558469
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://ieeexplore.ieee.org/document/7460101/
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectBOUNDARY CONDUCTION MODE (BCM)
dc.subjectCONTINUOUS CONDUCTION MODE (CCM)
dc.subjectINDUCTOR DESIGN
dc.subjectINTERLEAVED POWER CONVERTERS
dc.subjectPHOTOVOLTAIC (PV) CONVERTERS
dc.subjectPOWER FACTOR CORRECTION (PFC)
dc.titleInterleaved Boundary Conduction Mode Versus Continous Conduction Mode Magnetic Volume Comparison in Power Converters