dc.creatorMaso Talou, Gonzalo D.
dc.creatorLarrabide, Ignacio
dc.creatorBlanco, Pablo Javier
dc.creatorBezerra, Cristiano Guedes
dc.creatorLemos, Pedro A.
dc.creatorFeijóo, Raúl Antonino
dc.date.accessioned2018-08-10T20:00:48Z
dc.date.accessioned2018-11-06T11:28:43Z
dc.date.available2018-08-10T20:00:48Z
dc.date.available2018-11-06T11:28:43Z
dc.date.created2018-08-10T20:00:48Z
dc.date.issued2015-12
dc.identifierMaso Talou, Gonzalo D.; Larrabide, Ignacio; Blanco, Pablo Javier; Bezerra, Cristiano Guedes; Lemos, Pedro A.; et al.; Improving Cardiac Phase Extraction in IVUS Studies by Integration of Gating Methods; Institute of Electrical and Electronics Engineers; Ieee Transactions On Bio-medical Engineering; 62; 12; 12-2015; 2867-2877
dc.identifier0018-9294
dc.identifierhttp://hdl.handle.net/11336/54998
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1852890
dc.description.abstractGoal: Coronary intravascular ultrasound (IVUS) is a fundamental imaging technique for atherosclerotic plaque assessment. However, volume-based data retrieved from IVUS studies can be misleading due to the artifacts generated by the cardiac motion, hindering diagnostic, and visualization of the vessel condition. Then, we propose an image-based gating method that improves the performance of the preexisting methods, delivering a gating in an appropriate time for clinical practice. Methods: We propose a fully automatic method to synergically integrate motion signals from different gating methods to improve the cardiac phase estimation. Additionally, we present a local extrema identification method that provides a more accurate extraction of a cardiac phase and, also, a scheme for multiple phase extraction mandatory for elastography-type studies. Results: A comparison with three state-of-the-art methods is performed over 61 in-vivo IVUS studies including a wide range of physiological situations. The results show that the proposed strategy offers: 1) a more accurate cardiac phase extraction; 2) a lower frame oversampling and/or omission in the extracted phase data (error of 1.492 ± 0.977 heartbeats per study, mean ± SD); 3) a more accurate and robust heartbeat period detection with a Bland-Altman coefficient of reproducibility (RPC) of 0.23 s, while the second closest method presents an RPC of 0.36 s. Significance: The integration of motion signals performed by our method shown an improvement of the gating accuracy and reliability.
dc.languageeng
dc.publisherInstitute of Electrical and Electronics Engineers
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/https://dx.doi.org/10.1109/TBME.2015.2449232
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://ieeexplore.ieee.org/document/7132741/
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectGATING
dc.subjectINTRAVASCULAR ULTRASOUND (IVUS)
dc.subjectMOTION COMPENSATION AND ANALYSIS
dc.subjectULTRASOUND
dc.titleImproving Cardiac Phase Extraction in IVUS Studies by Integration of Gating Methods
dc.typeArtículos de revistas
dc.typeArtículos de revistas
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución