dc.creatorSatti, Angel Jose
dc.creatorRessia, Jorge Aníbal
dc.creatorCerrada, M. L.
dc.creatorAndreucetti, Noemi Amalia
dc.creatorValles, Enrique Marcelo
dc.date.accessioned2018-08-22T13:58:39Z
dc.date.accessioned2018-11-06T11:25:30Z
dc.date.available2018-08-22T13:58:39Z
dc.date.available2018-11-06T11:25:30Z
dc.date.created2018-08-22T13:58:39Z
dc.date.issued2017-09
dc.identifierSatti, Angel Jose; Ressia, Jorge Aníbal; Cerrada, M. L.; Andreucetti, Noemi Amalia; Valles, Enrique Marcelo; Rheological analysis of irradiated crosslinkable and scissionable polymers used for medical devices under different radiation conditions; Pergamon-Elsevier Science Ltd; Radiation Physics and Chemistry (Oxford); 144; 9-2017; 298-303
dc.identifier0969-806X
dc.identifierhttp://hdl.handle.net/11336/56514
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1851367
dc.description.abstractThe effects on different synthetic polymers of distinct types of radiation, gamma rays and electron beam, under different atmospheres are followed by changes in their viscoelastic behavior. Taking into account the two main radioinduced reactions, crosslinking and scissioning of polymeric chains, liquid polydimethylsiloxane has been used as example of crosslinkable polymer and semi crystalline polypropylene as example of scissionable polymer. Propylene − 1-hexene copolymers have been also evaluated, and the effects of both reactions were clearly noticed. Accordingly, samples of those aforementioned polymers have been irradiated with 60Co gamma irradiation in air and under vacuum, and also with electron beam, at similar doses. Sinusoidal dynamic oscillation experiments showed a significant increase in branching and crosslinking reactions when specimens are irradiated under vacuum, while scissioning reactions were observed for the different polymers when irradiation takes place under air with either gamma irradiation or electron beam.
dc.languageeng
dc.publisherPergamon-Elsevier Science Ltd
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0969806X17304346
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.radphyschem.2017.09.002
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.5/ar/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectELECTRON BEAM
dc.subjectGAMMA IRRADIATION
dc.subjectMETALLOCENIC POLYPROPYLENES
dc.subjectPOLYDIMETHYLSILOXANE
dc.subjectRHEOLOGY
dc.subjectVACUUM
dc.titleRheological analysis of irradiated crosslinkable and scissionable polymers used for medical devices under different radiation conditions
dc.typeArtículos de revistas
dc.typeArtículos de revistas
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución