dc.creator | Fernandez, Liliana Patricia | |
dc.creator | Peralta, Cecilia Mariana | |
dc.date.accessioned | 2016-05-20T20:42:53Z | |
dc.date.accessioned | 2018-11-06T11:15:28Z | |
dc.date.available | 2016-05-20T20:42:53Z | |
dc.date.available | 2018-11-06T11:15:28Z | |
dc.date.created | 2016-05-20T20:42:53Z | |
dc.date.issued | 2014-07 | |
dc.identifier | Fernandez, Liliana Patricia; Peralta, Cecilia Mariana; O-(β-hydroxyethyl)rutosides determination by micellar flow injection (FI) spectrofluorimetry; Elsevier; Journal of Pharmaceutical Analysis; 4; 6; 7-2014; 368-373 | |
dc.identifier | 2095-1779 | |
dc.identifier | http://hdl.handle.net/11336/5766 | |
dc.identifier.uri | http://repositorioslatinoamericanos.uchile.cl/handle/2250/1847777 | |
dc.description.abstract | A simple, eco friendly, sensitive and economic flow injection spectrofluorimetric method was developed for the determination of O-(β-hydroxyethyl)rutosides. The procedure was based on the use of an anionic surfactant such as sodium dodecyl sulfate to provide an appreciable O-(β- hydroxyethyl)rutosides fluorescence enhancement, increasing considerably the sensitivity of detection. All the variables affecting the fluorescence intensity were studied and optimized. The flow rate was 5 mL/min with detection at 450 nm (after excitation at 346 nm). A linear correlation between drug amount and peak area was established for O-(β-hydroxyethyl)rutosides in the range of 0.01 - 200 μg/mL with a detection limit of 0.001 μg/mL (s/n = 3). Validation processes were performed by recovering studies with satisfactory results. The new methodology can be employed for the routine analysis of O-(β-hydroxyethyl)rutosides in bulks as well as in commercial formulations. | |
dc.language | eng | |
dc.publisher | Elsevier | |
dc.relation | info:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S2095177914000628 | |
dc.relation | info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.jpha.2014.07.002 | |
dc.relation | info:eu-repo/semantics/altIdentifier/doi/10.1016/j.jpha.2014.07.002 | |
dc.rights | https://creativecommons.org/licenses/by-nc-nd/2.5/ar/ | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.subject | O-(β-HYDROXYETHYL)RUTOSIDES | |
dc.subject | MICELLAR ENHANCEMENT | |
dc.subject | FLOW INJECTION | |
dc.subject | SPECTROFLUORIMETRY | |
dc.subject | PHARMACEUTICALS | |
dc.title | O-(β-hydroxyethyl)rutosides determination by micellar flow injection (FI) spectrofluorimetry | |
dc.type | Artículos de revistas | |
dc.type | Artículos de revistas | |
dc.type | Artículos de revistas | |