Argentina | Artículos de revistas
dc.creatorUllio Gamboa, Gabriela Veronica
dc.creatorLlabot, Juan Manuel
dc.creatorSánchez Vallecillo, María Fernanda
dc.creatorMaletto, Belkys Angélica
dc.creatorPalma, Santiago Daniel
dc.creatorAllemandi, Daniel Alberto
dc.date.accessioned2018-05-24T14:15:22Z
dc.date.accessioned2018-11-06T11:07:03Z
dc.date.available2018-05-24T14:15:22Z
dc.date.available2018-11-06T11:07:03Z
dc.date.created2018-05-24T14:15:22Z
dc.date.issued2015-03
dc.identifierUllio Gamboa, Gabriela Veronica; Llabot, Juan Manuel; Sánchez Vallecillo, María Fernanda; Maletto, Belkys Angélica; Palma, Santiago Daniel; et al.; Development and validation of a high performance liquid 4 chromatography method for oligodeoxynucleotides determination 5 in a novel coagel-based formulation; Elsevier; Analytical Chemical Research; 4; 3-2015; 20-24
dc.identifier2214-1812
dc.identifierhttp://hdl.handle.net/11336/46049
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1846101
dc.description.abstractThe therapeutic benefit of phosphorothioate oligodeoxynucleotides (PS-ODN) containing immune stimulatory sequences has been demonstrated in animal models of cancer and infection. Several tools are available for the determination of these oligonucleotides in biological samples and pharmaceutical preparations, including UV spectroscopy, dye binding, isotopic tracing, capillary gel electrophoresis (CGE), hybridization-based enzyme-linked immunosorbent assay (ELISA), and chromatography techniques. However, due to inter-assay variability and accuracy problems associated with the afore mentioned methods, we have developed and validated an isocratic high performance liquid chromatographic (HPLC) for analytical determination of PS-ODN containing unmethylated CpG motifs (CpG-ODN). Validation under Food and Drug Administration (FDA) guidelines of the analytical parameters include: linearity (r2 0.9996), LOD (0.86 lg/ml) and LOQ (6.25 lg/ml), intra (0.19?3.37%) and inter-day precision (0.63?3.75%) expressed as relative standard deviation (RSD), and robustness parameters (less than 2.80%). Using this method, recoveries ranging from 89.9% to 99.9% were obtained. Thus, this method provides a simple, sensitive, precise and reproducible examination which can be readily adapted for the assessment of CpG-ODN in different pharmaceutical preparations.
dc.languageeng
dc.publisherElsevier
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.ancr.2015.03.003
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S2214181215000075
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectASCORBYL PALMITATE LIQUID CRYSTALS
dc.subjectLIQUID CHROMATOGRAPHY
dc.subjectNUCLEASE STABILITY
dc.subjectOLIGONUCLEOTIDES
dc.titleDevelopment and validation of a high performance liquid 4 chromatography method for oligodeoxynucleotides determination 5 in a novel coagel-based formulation
dc.typeArtículos de revistas
dc.typeArtículos de revistas
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución