RM de corpo inteiro: avaliação de protocolo em equipamento 3T com 48 canais em menos de 40 minutos. Resultados preliminares

dc.creatorHernandes, Mateus de Andrade
dc.creatorSemelka, Richard C.
dc.creatorElias Júnior, Jorge
dc.creatorBamrungchart, Saraporn
dc.creatorDale, Brian M.
dc.creatorStallings, Clifton
dc.date.accessioned2013-11-04T12:13:42Z
dc.date.accessioned2018-07-04T16:33:02Z
dc.date.available2013-11-04T12:13:42Z
dc.date.available2018-07-04T16:33:02Z
dc.date.created2013-11-04T12:13:42Z
dc.date.issued2012
dc.identifierRadiol Bras,v.45,n.6,p.319-325,2012
dc.identifier0100-3984
dc.identifierhttp://www.producao.usp.br/handle/BDPI/38579
dc.identifier10.1590/S0100-39842012000600007
dc.identifierhttp://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842012000600007&lng=en&nrm=iso&tlng=en
dc.identifierhttp://www.scielo.br/scielo.php?script=sci_abstract&pid=S0100-39842012000600007&lng=en&nrm=iso&tlng=en
dc.identifierhttp://www.scielo.br/scielo.php?script=sci_pdf&pid=S0100-39842012000600007&lng=en&nrm=iso&tlng=en
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1637124
dc.description.abstractOBJECTIVE: To evaluate a comprehensive MRI protocol that investigates for cancer, vascular disease, and degenerative/inflammatory disease from the head to the pelvis in less than 40 minutes on a new generation 48-channel 3T system. MATERIALS AND METHODS: All MR studies were performed on a 48-channel 3T MR scanner. A 20-channel head/neck coil, two 18-channel body arrays, and a 32-channel spine array were employed. A total of 4 healthy individuals were studied. The designed protocol included a combination of single-shot T2-weighted sequences, T1-weighted 3D gradient-echo pre- and post-gadolinium. All images were retrospectively evaluated by two radiologists independently for overall image quality. RESULTS: The image quality for cancer was rated as excellent in the liver, pancreas, kidneys, lungs, pelvic organs, and brain, and rated as fair in the colon and breast. For vascular diseases ratings were excellent in the aorta, major branch vessel origins, inferior vena cava, portal and hepatic veins, rated as good in pulmonary arteries, and as poor in the coronary arteries. For degenerative/inflammatory diseases ratings were excellent in the brain, liver and pancreas. The inter-observer agreement was excellent. CONCLUSION: A comprehensive and time efficient screening for important categories of disease processes may be achieved with high quality imaging in a new generation 48-channel 3T system.
dc.languageeng
dc.publisherColégio Brasileiro de Radiologia e Diagnóstico por Imagem
dc.relationRadiologia Brasileira
dc.rightsopenAccess
dc.subjectWhole-body MRI
dc.subjectScreening
dc.subjectProtocol
dc.subjectPreliminary results
dc.subject3 tesla
dc.subjectRM de corpo inteiro
dc.subjectScreening
dc.subjectProtocolo
dc.subjectResultados preliminares
dc.subject3 tesla
dc.titleWhole-body MRI: comprehensive evaluation on a 48-channel 3T MRI system in less than 40 minutes. Preliminary results
dc.titleRM de corpo inteiro: avaliação de protocolo em equipamento 3T com 48 canais em menos de 40 minutos. Resultados preliminares
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución