dc.creatorde Oliveira Neto, Patricio Jose
dc.creatorCricchio, Giovanni
dc.creatorHawthorne, Ana Carolina
dc.creatorOkamoto, Roberta
dc.creatorSennerby, Lars
dc.creatorLungren, Stefan
dc.creatorSalata, Luiz Antonio
dc.date.accessioned2013-10-22T10:35:17Z
dc.date.accessioned2018-07-04T16:25:43Z
dc.date.available2013-10-22T10:35:17Z
dc.date.available2018-07-04T16:25:43Z
dc.date.created2013-10-22T10:35:17Z
dc.date.issued2012
dc.identifierCLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, HOBOKEN, v. 14, n. 6, supl. 1, Part 1, pp. 861-871, DEC, 2012
dc.identifier1523-0899
dc.identifierhttp://www.producao.usp.br/handle/BDPI/35498
dc.identifier10.1111/j.1708-8208.2010.00321.x
dc.identifierhttp://dx.doi.org/10.1111/j.1708-8208.2010.00321.x
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1635712
dc.description.abstractBackground: The bone tissue responses to Cyanoacrylate have been described in the literature, but none used N-butyl-2-cyanoacrilate (NB-Cn) for bone graft fixation. Purpose: The aims of the study were: (a) to analyze the bone grafts volume maintenance fixed either with NB-Cn or titanium screw; (b) to assess the incorporation of onlay grafts on perforated recipient bed; and (c) the differences of expression level of tartrate-resistant acid phosphatase (TRAP) protein involved in bone resorption. Materials and Methods: Eighteen New Zealand White rabbits were submitted to calvaria onlay grafting on both sides of the mandible. On one side, the graft was fixed with NB-Cn, while on the other hand the bone graft was secured with an osteosynthesis screw. The computed tomography (CT) was performed just after surgery and at animals sacrifice, after 1 (n = 9) and 6 weeks (n = 9), in order to estimate the bone grafts volume along the experiments. Histological sections of the grafted areas were prepared to evaluate the healing of bone grafts and to assess the expression of TRAP protein. Results: The CT scan showed better volume maintenance of bone grafts fixed with NB-Cn (p = 0.05) compared with those fixed with screws, in both experimental times (analysis of variance). The immunohistochemical evaluation showed that the TRAP expression in a 6-week period was significantly higher compared with the 1-week period, without showing significant difference between the groups (Wilcoxon and MannWhitney). Histological analysis revealed that the NB-Cn caused periosteum damage, but provided bone graft stabilization and incorporation similar to the control group. Conclusion: The perforation provided by screw insertion into the graft during fixation may have triggered early revascularization and remodeling to render increased volume loss compared with the experimental group. These results indicate that the NB-Cn possesses equivalent properties to titanium screw to be used as bone fixation material in osteosynthesis.
dc.languageeng
dc.publisherWILEY-BLACKWELL
dc.publisherHOBOKEN
dc.relationCLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH
dc.rightsCopyright WILEY-BLACKWELL
dc.rightsrestrictedAccess
dc.subjectBONE GRAFT FIXATION
dc.subjectCYANOCRYLATE
dc.subjectHEALING BONE
dc.subjectHISTOLOGIC EVALUATION
dc.subjectIMMUNOHISTOCHEMISTRY
dc.subjectONLAY BONE GRAFT
dc.subjectTOMOGRAPHIC EVALUATION
dc.titleTomographic, Histological, and Immunohistochemical Evidences on the Use of N-Butyl-2-Cyanoacrilate for Onlay Graft Fixation in Rabbits
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución