dc.creator | Netto, Antonio Pedro de Oliveira | |
dc.creator | Zaiat, Marcelo | |
dc.date.accessioned | 2013-11-06T16:29:16Z | |
dc.date.accessioned | 2018-07-04T16:16:32Z | |
dc.date.available | 2013-11-06T16:29:16Z | |
dc.date.available | 2018-07-04T16:16:32Z | |
dc.date.created | 2013-11-06T16:29:16Z | |
dc.date.issued | 2012 | |
dc.identifier | CLEAN-SOIL AIR WATER, HOBOKEN, v. 40, n. 9, p. 965-971, SEP, 2012 | |
dc.identifier | 1863-0650 | |
dc.identifier | http://www.producao.usp.br/handle/BDPI/42352 | |
dc.identifier | 10.1002/clen.201100672 | |
dc.identifier | http://dx.doi.org/10.1002/clen.201100672 | |
dc.identifier.uri | http://repositorioslatinoamericanos.uchile.cl/handle/2250/1633734 | |
dc.description.abstract | This study reports the performance of a combined anaerobic-aerobic packed-bed reactor that can be used to treat domestic sewage. Initially, a bench-scale reactor was operated in three experimental phases. In the first phase, the anaerobic reactor was operated with an average organic matter removal efficiency of 77% for a hydraulic retention time (HRT) of 10 h. In the second phase, the reactor was operated with an anaerobic stage followed by an aerobic zone, resulting in a mean value of 91% efficiency. In the third and final phase, the anaerobic-aerobic reactor was operated with recirculation of the effluent of the reactor through the anaerobic zone. The system yielded mean total nitrogen removal percentages of 65 and 75% for recycle ratios (r) of 0.5 and 1.5, respectively, and the chemical oxygen demand (COD) removal efficiencies were higher than 90%. When the pilot-scale reactor was operated with an HRT of 12 h and r values of 1.5 and 3.0, its performance was similar to that observed in the bench-scale unit (92% COD removal for r = 3.0). However, the nitrogen removal was lower (55% N removal for r = 3.0) due to problems with the hydrodynamics in the aerobic zone. The anaerobic-aerobic fixed-bed reactor with recirculation of the liquid phase allows for concomitant carbon and nitrogen removal without adding an exogenous source of electron donors and without requiring any additional alkalinity supplementation. | |
dc.language | eng | |
dc.publisher | WILEY-BLACKWELL | |
dc.publisher | HOBOKEN | |
dc.relation | CLEAN-SOIL AIR WATER | |
dc.rights | Copyright WILEY-BLACKWELL | |
dc.rights | closedAccess | |
dc.subject | ANAEROBIC-AEROBIC TREATMENT | |
dc.subject | DENITRIFICATION | |
dc.subject | IMMOBILIZED BIOMASS | |
dc.subject | NITRIFICATION | |
dc.title | Treatment of Domestic Sewage in an Anaerobic-Aerobic Fixed-bed Reactor with Recirculation of the Liquid Phase | |
dc.type | Artículos de revistas | |