dc.creatorTakimura, Celso Kiyochi
dc.creatorWatanabe, Ii-sei
dc.creatorMartins Laurindo, Francisco Rafael
dc.creatorGutierrez, Paulo Sampaio
dc.creatorAiello, Vera Demarchi
dc.creatorMorato, Spero Penha
dc.creatorLemos Neto, Pedro Alves
dc.date.accessioned2013-11-01T11:57:53Z
dc.date.accessioned2018-07-04T16:09:11Z
dc.date.available2013-11-01T11:57:53Z
dc.date.available2018-07-04T16:09:11Z
dc.date.created2013-11-01T11:57:53Z
dc.date.issued2012
dc.identifierARQUIVOS BRASILEIROS DE CARDIOLOGIA, RIO DE JANEIRO, v. 99, n. 6, supl., Part 1, pp. 1123-1127, DEC, 2012
dc.identifier0066-782X
dc.identifierhttp://www.producao.usp.br/handle/BDPI/37491
dc.identifier10.1590/S0066-782X2012005000103 
dc.identifierhttp://dx.doi.org/10.1590/S0066-782X2012005000103 
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1632117
dc.description.abstractBackground: Fast post-implantation stent endothelialization is desirable for theoretically reducing the possibility of stent thrombosis. Objective: To evaluate the extent of sirolimus-eluting stent strut endothelialization (delivered from the luminal and abluminal aspects or abluminal aspect only) in the iliac arteries of rabbits. Methods: The iliac arteries of 10 rabbits were implanted with four sirolimus-eluting stents in the luminal and abluminal aspects, three sirolimus-eluting stents in the abluminal aspect, six polymer-coated stents, and four uncoated stents. After four weeks, the rabbits were euthanized and scanning electron microscopy was performed to quantify the area of exposed stent strut as well as the percentage of endothelialization. Results: The area (mean +/- SD) (mm(2)) of exposed uncoated stent struts, polymer-coated stents, sirulimus-eluting stent in the abluminal and luminal aspects and sirolimus-eluting stent in the abluminal aspect was 0.12 +/- 0.08, 0.09 +/- 0.12, 0.60 +/- 0.67 and 0.05 +/- 0.04, respectively (p = 0.120). The percentage of endothelialization (mean +/- SD) (%) of uncoated stents, polymer-coated stents, sirolimus-eluting stents in the luminal and abluminal aspects and sirolimus-eluting stents in the abluminal aspect was 99 +/- 01, 99 +/- 0. 97 +/- 03 and 99 +/- 0, respectively (p = 0.133). Conclusion: After four weeks of implantation in the iliac arteries of rabbits, both the sirolimus-eluting stents in the luminal plus abluminal aspects and those in the abluminal aspect only showed stent strut endothelialization rates similar to those of the other types of non-drug eluting stents. (Arq Bras Cardiol 2012;99(6):1123-1128)
dc.languageeng
dc.publisherARQUIVOS BRASILEIROS CARDIOLOGIA
dc.publisherRIO DE JANEIRO
dc.relationARQUIVOS BRASILEIROS DE CARDIOLOGIA
dc.rightsCopyright ARQUIVOS BRASILEIROS CARDIOLOGIA
dc.rightsopenAccess
dc.subjectDRUG ELUTING STENTS
dc.subjectARTERIES
dc.subjectSIROLIMUS
dc.subjectMICROSCOPY, ELECTRON, SCANNING
dc.titleAssessment of Stent Strut Endothelialization in Iliac Arteries of Rabbits
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución