dc.description.abstractPURPOSE. The aim of the present study was to evaluate if a smaller morse taper abutment has a negative effect on the fracture resistance of implant-abutment connections under oblique compressive loads compared to a conventional abutment MATERIALS AND METHODS. Twenty morse taper conventional abutments (4.8 mm diameter) and smaller abutments (3.8 mm diameter) were tightened (20 Ncm) to their respective implants (3.5 x 11 mm) and after a 10 minute interval, implant/abutment assemblies were subjected to static compressive test, performed in a universal test machine with 1 mm/min displacement, at 45 degrees inclination. The maximum deformation force was determined. Data were statistically analyzed by student t test. RESULTS. Maximum deformation force of 4.8 mm and 3.8 mm abutments was approximately 95.33 kgf and 95.25 kgf, respectively, but no fractures were noted after mechanical test. Statistical analysis demonstrated that the evaluated abutments were statistically similar (P=.230). CONCLUSION. Abutment measuring 3.8 mm in diameter (reduced) presented mechanical properties similar to 4.8 mm (conventional) abutments, enabling its clinical use as indicated. [J Adv Prosthodont 2012;4:158-61]
dc.languageeng
dc.publisherKOREAN ACAD PROSTHODONTICS
dc.publisherSEOUL
dc.relationJOURNAL OF ADVANCED PROSTHODONTICS
dc.rightsCopyright KOREAN ACAD PROSTHODONTICS
dc.rightsopenAccess
dc.subjectDENTAL IMPLANTS
dc.subjectDENTAL IMPLANT ABUTMENT DESIGN
dc.subjectMORSE TAPER DENTAL IMPLANT ABUTMENT CONNECTION
dc.subjectCOMPRESSIVE STRENGTH
dc.titleMechanical analysis of conventional and small diameter conical implant abutments
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución