dc.creatorAquino, Evanirso Silva
dc.creatorShimura, Francine
dc.creatorSantos, Adriana Silveira
dc.creatorGoto, Danielle Miyuki
dc.creatorCoelho, Cristiane Cenachi
dc.creatorde Fuccio, Marcelo Bicalho
dc.creatorNascimento Saldiva, Paulo Hilario
dc.creatorLorenzi-Filho, Geraldo
dc.creatorRubin, Bruce K.
dc.creatorNakagawa, Naomi Kondo
dc.date.accessioned2013-10-29T13:01:09Z
dc.date.accessioned2018-07-04T16:04:43Z
dc.date.available2013-10-29T13:01:09Z
dc.date.available2018-07-04T16:04:43Z
dc.date.created2013-10-29T13:01:09Z
dc.date.issued2013-08-02
dc.identifierRESPIRATORY CARE, IRVING, v. 57, n. 11, supl. 1, Part 3, pp. 1914-1919, NOV, 2012
dc.identifier0020-1324
dc.identifierhttp://www.producao.usp.br/handle/BDPI/36294
dc.identifier10.4187/respcare.01705
dc.identifierhttp://dx.doi.org/10.4187/respcare.01705
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1631325
dc.description.abstractBACKGROUND: Positive expiratory pressure (PEP) is used for airway clearance in cystic fibrosis (CF) patients. Hypertonic saline (HTS) aerosol increases sputum expectoration volume and may improve respiratory secretion properties. CPAP may also be used to maintain airway patency and mobilize secretions. To evaluate if CPAP would increase the beneficial clearance effect of HTS in subjects with CF, we investigated the effects of CPAP alone and CPAP followed by HTS on sputum physical properties and expectoration volume in CF subjects. METHODS: In this crossover study, 15 CF subjects (mean age 19 y old) were randomized to interventions, 48 hours apart: directed coughs (control), CPAP at 10 cm H2O, HTS 7%, and both CPAP and HTS (CPAP+HTS). Sputum collection was performed at baseline and after interventions. Expectorated volume was determined and in vitro sputum properties were analyzed for contact angle and cough clearability. RESULTS: There were no significant differences between any treatment in arterial blood pressure, heart rate, or pulse oximetry, between the 2 time points. HTS and CPAP+HTS improved cough clearability by 50% (P = .001) and expectorated volume secretion by 530% (P = .001). However, there were no differences between control and CPAP on sputum contact angle, cough clearability, or volume of expectorated secretion. CONCLUSIONS: CPAP alone had no effect on mucus clearance, sputum properties, or expectorated volume, and did not potentiate the effect of HTS alone in CF subjects.
dc.languageeng
dc.publisherDAEDALUS ENTERPRISES INC
dc.publisherIRVING
dc.relationRESPIRATORY CARE
dc.rightsCopyright DAEDALUS ENTERPRISES INC
dc.rightsclosedAccess
dc.subjectCOUGH CLEARANCE
dc.subjectHYPERTONIC SALINE
dc.subjectCONTINUOUS POSITIVE AIRWAY PRESSURE
dc.subjectSPUTUM, CYSTIC FIBROSIS
dc.titleCPAP Has No Effect on Clearance, Sputum Properties, or Expectorated Volume in Cystic Fibrosis