dc.creatorTaborianski, Vanessa Montoro
dc.creatorPrado, Racine Tadeu Araujo
dc.date.accessioned2013-08-12T14:17:01Z
dc.date.accessioned2018-07-04T15:55:13Z
dc.date.available2013-08-12T14:17:01Z
dc.date.available2018-07-04T15:55:13Z
dc.date.created2013-08-12T14:17:01Z
dc.date.issued2012
dc.identifierEnvironmental Impact Assessment Review, New York, v. 33, n. 1, supl. 4, Part 1-2, pp. 41-47, FEB, 2012
dc.identifier0195-9255
dc.identifierhttp://www.producao.usp.br/handle/BDPI/32535
dc.identifier10.1016/j.eiar.2011.10.004
dc.identifierhttp://dx.doi.org/10.1016/j.eiar.2011.10.004
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1629206
dc.description.abstractThe construction industry is one of the greatest sources of pollution because of the high level of energy consumption during its life cycle. In addition to using energy while constructing a building, several systems also use power while the building is operating, especially the air-conditioning system. Energy consumption for this system is related, among other issues, to external air temperature and the required internal temperature of the building. The facades are elements which present the highest level of ambient heat transfer from the outside to the inside of tall buildings. Thus, the type of facade has an influence on energy consumption during the building life cycle and, consequently, contributes to buildings' CO2 emissions, because these emissions are directly connected to energy consumption. Therefore, the aim is to help develop a methodology for evaluating CO2 emissions generated during the life cycle of office building facades. The results, based on the parameters used in this study, show that facades using structural glazing and uncolored glass emit the most CO2 throughout their life cycle, followed by brick facades covered with compound aluminum panels or ACM (Aluminum Composite Material), facades using structural glazing and reflective glass and brick facades with plaster coating. On the other hand, the typology of facade that emits less CO2 is brickwork and mortar because its thermal barrier is better than structural glazing facade and materials used to produce this facade are better than brickwork and ACM. Finally, an uncertainty analysis was conducted to verify the accuracy of the results attained. (C) 2011 Elsevier Inc. All rights reserved.
dc.languageeng
dc.publisherELSEVIER SCIENCE INC
dc.publisherNEW YORK
dc.relationENVIRONMENTAL IMPACT ASSESSMENT REVIEW
dc.rightsCopyright ELSEVIER SCIENCE INC
dc.rightsopenAccess
dc.subjectCO2 EMISSIONS
dc.subjectBUILDING FACADE
dc.subjectLIFE CYCLE ASSESSMENT
dc.titleMethodology of CO2 emission evaluation in the life cycle of office building facades
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución