dc.creatorSilva, Giulliano Guimaraes
dc.creatorNaval, Liliana Pena
dc.creatorDi Bernardo, Luiz
dc.creatorDantas, Angela Di Bernardo
dc.date.accessioned2013-08-21T23:08:54Z
dc.date.accessioned2018-07-04T15:55:09Z
dc.date.available2013-08-21T23:08:54Z
dc.date.available2018-07-04T15:55:09Z
dc.date.created2013-08-21T23:08:54Z
dc.date.issued2012
dc.identifierENGENHARIA SANITARIA E AMBIENTAL, RIO DE JANEIRO, v. 17, n. 1, pp. 71-80, JAN-MAR, 2012
dc.identifier1413-4152
dc.identifierhttp://www.producao.usp.br/handle/BDPI/32664
dc.identifier10.1590/S1413-41522012000100011
dc.identifierhttp://dx.doi.org/10.1590/S1413-41522012000100011
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1629194
dc.description.abstractEste trabalho teve como objetivo avaliar o tratamento de água bruta proveniente de um reservatório de água, utilizando instalação piloto de dupla filtração (DF), composta por filtro ascendente de pedregulho (FAP) e filtro rápido descendente de areia (FRD), seguida de uma unidade de pós-tratamento com carvão ativado granular (CAG). Adicionalmente, foi verificado o efeito da pré e interoxidação (entre o FAP e o FRD) na eficiência global do tratamento e na formação de subprodutos orgânicos halogenados (SOH). Em função dos resultados obtidos, foi observado que a pré-oxidação melhorou a qualidade do efluente do FAP e a interoxidação favoreceu que resultassem valores menores de turbidez e cor no efluente do FRD. O processo de tratamento por adsorção em carvão ativado granular, utilizado como pós-tratamento, mostrou-se eficiente para assegurar a qualidade dos efluentes finais nos ensaios realizados, especialmente, em relação à remoção de matéria orgânica, cianobactérias e cor. As concentrações máximas de SOH encontrados nos efluentes do FRD e do FCAG não ultrapassaram os valores limites da Portaria nº 2.914/2011 do Ministério da Saúde.
dc.description.abstractThis study evaluated the treatment of raw lake water using a double filtration (DF) pilot plant consisting of an up-flow gravel filter (UGF) in series with a down-flow sand filter (DSF) and followed by a post-treatment granular activated carbon (GAC) unit. Additionally, the study examines the effect of pre and inter-oxidation (between UGF and DSF) on overall efficiency in the treatment and the formation of halogenated organic byproducts (HOB). According to the results obtained, it was observed that the pre-oxidation improved the quality of the UGF effluent and the inter-oxidation favored lower values of turbidity and color in the DSF effluent. Also, the treatment process by adsorption on granular activated carbon, used as a post-treatment, was efficient to ensure the quality of final effluent in the tests, especially regarding the removal of organic matter, cyanobacteria, and color. The maximum concentrations of HOB found in the effluents from the DSF and GAC did not exceed the limits of the Brazilian drinking water standards (Portaria no 2.914/2011).
dc.languagepor
dc.publisherASSOC BRASILEIRA ENGENHARIA SANITARIA AMBIENTAL
dc.publisherRIO DE JANEIRO
dc.relationENGENHARIA SANITARIA E AMBIENTAL
dc.rightsCopyright ASSOC BRASILEIRA ENGENHARIA SANITARIA AMBIENTAL
dc.rightsopenAccess
dc.subjectDOUBLE FILTRATION
dc.subjectOXIDATION
dc.subjectCHLORINE
dc.subjectADSORPTION
dc.subjectGRANULAR ACTIVATED CARBON
dc.subjectHALOGENATED ORGANIC BYPRODUCTS
dc.titleTratamento de água de reservatórios por dupla filtração, oxidação e adsorção em carvão ativado granular
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución