dc.creatorKHOURY, H. J.
dc.creatorGUZZO, P. L.
dc.creatorSOUZA, L. B. F.
dc.creatorFarias, Thiago Michel de Brito
dc.creatorWatanabe, Shigueo
dc.date.accessioned2012-10-20T04:11:58Z
dc.date.accessioned2018-07-04T15:40:56Z
dc.date.available2012-10-20T04:11:58Z
dc.date.available2018-07-04T15:40:56Z
dc.date.created2012-10-20T04:11:58Z
dc.date.issued2008
dc.identifierRADIATION MEASUREMENTS, v.43, n.2/Jun, p.487-491, 2008
dc.identifier1350-4487
dc.identifierhttp://producao.usp.br/handle/BDPI/29437
dc.identifier10.1016/j.radmeas.2008.01.028
dc.identifierhttp://dx.doi.org/10.1016/j.radmeas.2008.01.028
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1626077
dc.description.abstractThe aim of this paper is to report the sensitization of the TL peak appearing at 270 degrees C in the glow curve of natural quartz by using the combined effect of heat-treatments and irradiation with high gamma doses. For this, thirty discs with 6 x 1 mm(2) were prepared from plates parallell to a rhombolledral crystal face. The specimens were separated into four lots according to its TL read out between 160 and 320 degrees C. One lot was submitted to gamma doses of Co-60 radiation starting at 2 kGy and going up until a cumulative dose of 25 kGy. The other three lots were initially heal-treated at 500, 800 and 1000 degrees C and then irradiated with a single dose of 25kGy. The TL response of each lot was determined as a function of test-doses ranging from 0.1 to 30 mGy. As a result, it was observed that heat-treatments themselves did not produce the strong peak at 270 degrees C that was observed after the administration of high gamma doses. This peak is associated with the optical absorption band appearing at 470 rim which is due to the formation of [AlO4]degrees acting as electron-hole recombination centers. The formation of the 270 degrees C peak was preliminary analyzed in relation to aluminum- and oxygen-vacancy-related centers found in crystalline quartz. (C) 2008 Elsevier Ltd. All rights reserved.
dc.languageeng
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD
dc.relationRadiation Measurements
dc.rightsCopyright PERGAMON-ELSEVIER SCIENCE LTD
dc.rightsrestrictedAccess
dc.subjectquartz single crystal
dc.subjectthermoluminescence
dc.subjectgamma-rays
dc.subjectpre-dose
dc.subjectheat-treatment
dc.subjectAl-hole center
dc.titleTL dosimetry of natural quartz sensitized by heat-treatment and high dose irradiation
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución