dc.creatorGONCALVES, Mariane
dc.creatorCORONA, Silmara Aparecida Milori
dc.creatorPALMA-DIBB, Regina Guenka
dc.creatorPECORA, Jesus Djalma
dc.date.accessioned2012-10-20T01:20:34Z
dc.date.accessioned2018-07-04T15:26:46Z
dc.date.available2012-10-20T01:20:34Z
dc.date.available2018-07-04T15:26:46Z
dc.date.created2012-10-20T01:20:34Z
dc.date.issued2008
dc.identifierJOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, v.86A, n.2, p.477-482, 2008
dc.identifier1549-3296
dc.identifierhttp://producao.usp.br/handle/BDPI/26383
dc.identifier10.1002/jbm.a.31636
dc.identifierhttp://dx.doi.org/10.1002/jbm.a.31636
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1623047
dc.description.abstractThe study evaluated the in vitro influence of pulse-repetition rate of Er:YAG laser and dentin depth on tensile bond strength of dentin-resin interface. Dentin surfaces of buccal or lingual surfaces from human third molars were submitted to tensile test in different depths (superficial, 1.0 and 1.5 mm) of the same dental area, using the same sample. Surface treatments were acid conditioning solely (control) and Er:YAG laser irradiation (80 mJ) followed by acid conditioning, with different pulse-repetition rates (1, 2, 3, or 4 Hz). Single bond/Z-250 system was used. The samples were stored in distilled water at 37 degrees C for 24 h, and then the first test (superficial dentine) was performed. The bond failures were analyzed. Following, the specimens were identified, grounded until 1.0- and 1.5-mm depths, submitted again to the treatments and to the second and, after that, to third-bond tests on a similar procedure and failure analysis. ANOVA and Tukey test demonstrated a significant difference (p < 0.001) for treatment and treatment X depth interaction (p < 0.05). The tested depths did not show influence (p > 0.05) on the bond strength of dentin-resin interface. It may be concluded that Er:YAG laser with 1, 2, 3, or 4 Hz combined with acid conditioning did not increase the resin tensile bond strength to dentin, regardless of dentin depth. (C) 2007 Wiley Periodicals, Inc.
dc.languageeng
dc.publisherWILEY-LISS
dc.relationJournal of Biomedical Materials Research Part A
dc.rightsCopyright WILEY-LISS
dc.rightsrestrictedAccess
dc.subjectdentin
dc.subjectEr : YAG laser
dc.subjecttensile bond strength
dc.subjectdentin depth
dc.subjectsurface treatment
dc.titleInfluence of pulse repetition rate of Er : YAG laser and dentin depth on tensile bond strength of dentin-resin interface
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución