dc.description.abstractP>This study assessed the effect of simulated mastication on the retention of two stud attachment systems for 2-implants overdentures. Sixteen specimens, each simulating an edentulous ridge with implants and an overdenture were divided into two groups, according to the attachment system: Group I (Nobel Biocare ball-socket attachments) and Group II (Locator attachments). Retention forces were measured before and after 400 000 simulated masticatory loads in a customised device. Data were compared by two-way anova followed by Bonferroni test (alpha = 0 center dot 05). Group I presented significantly lower retention forces (Newtons) than Group II at baseline (10 center dot 6 +/- 3 center dot 6 and 66 center dot 4 +/- 16 center dot 0, respectively). However, differences were not significant after 400 000 loads (7 center dot 9 +/- 4 center dot 3 and 21 center dot 6 +/- 17 center dot 0). The number of cycles did not influence the measurements in Group I, whereas a non-linear descending curve was found for Group II. It was concluded that simulated mastication resulted in minor changes for the ball attachment tested. Nevertheless, it reduced the retention of Locator attachments to 40% of the baseline values, what suggests that mastication is a major factor associated with maintenance needs for this system.
dc.languageeng
dc.publisherWILEY-BLACKWELL PUBLISHING, INC
dc.relationJournal of Oral Rehabilitation
dc.rightsCopyright WILEY-BLACKWELL PUBLISHING, INC
dc.rightsrestrictedAccess
dc.subjectdental implants
dc.subjectdenture retention
dc.subjectattachment
dc.subjectoverdenture
dc.subjectsimulated loading
dc.titleEffect of simulated masticatory loading on the retention of stud attachments for implant overdentures
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución