dc.creatorSILVA, Gyl Eanes Barros
dc.creatorCOSTA, Roberto Silva
dc.creatorRAVINAL, Roberto Cuan
dc.creatorSILVA, Jucelia Saraiva E
dc.creatorDANTAS, Marcio
dc.creatorCOIMBRA, Terezila Machado
dc.date.accessioned2012-10-19T23:32:26Z
dc.date.accessioned2018-07-04T15:19:01Z
dc.date.available2012-10-19T23:32:26Z
dc.date.available2018-07-04T15:19:01Z
dc.date.created2012-10-19T23:32:26Z
dc.date.issued2010
dc.identifierNEPHROLOGY, v.15, n.2, p.171-177, 2010
dc.identifier1320-5358
dc.identifierhttp://producao.usp.br/handle/BDPI/24759
dc.identifier10.1111/j.1440-1797.2009.01197.x
dc.identifierhttp://dx.doi.org/10.1111/j.1440-1797.2009.01197.x
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1621485
dc.description.abstractAim: To demonstrate that the evaluation of erythrocyte dysmorphism by light microscopy with lowering of the condenser lens (LMLC) is useful to identify patients with a haematuria of glomerular or non-glomerular origin. Methods: A comparative double-blind study between phase contrast microscopy (PCM) and LMLC is reported to evaluate the efficacy of these techniques. Urine samples of 39 patients followed up for 9 months were analyzed, and classified as glomerular and non-glomerular haematuria. The different microscopic techniques were compared using receiver-operator curve (ROC) analysis and area under curve (AUC). Reproducibility was assessed by coefficient of variation (CV). Results: Specific cut-offs were set for each method according to their best rate of specificity and sensitivity as follows: 30% for phase contrast microscopy and 40% for standard LMLC, reaching in the first method the rate of 95% and 100% of sensitivity and specificity, respectively, and in the second method the rate of 90% and 100% of sensitivity and specificity, respectively. In ROC analysis, AUC for PCM was 0.99 and AUC for LMLC was 0.96. The CV was very similar in glomerular haematuria group for PCM (35%) and LMLC (35.3%). Conclusion: LMLC proved to be effective in contributing to the direction of investigation of haematuria, toward the nephrological or urological side. This method can substitute PCM when this equipment is not available.
dc.languageeng
dc.publisherWILEY-BLACKWELL PUBLISHING, INC
dc.relationNephrology
dc.rightsCopyright WILEY-BLACKWELL PUBLISHING, INC
dc.rightsrestrictedAccess
dc.subjectglomerular disease
dc.subjecthaematuria
dc.subjectphase contrast microscopy
dc.subjecturinary dysmorphic erythrocytes
dc.subjecturine erythrocyte morphology
dc.titleEvaluation of erythrocyte dysmorphism by light microscopy with lowering of the condenser lens: A simple and efficient method
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución