dc.creatorRUANO, Rodrigo
dc.creatorAUBRY, Marie-Cecile
dc.creatorBARTHE, Bruno
dc.creatorDUMEZ, Yves
dc.creatorZUGAIB, Marcelo
dc.creatorBENACHI, Alexandra
dc.date.accessioned2012-10-19T17:31:44Z
dc.date.accessioned2018-07-04T15:08:27Z
dc.date.available2012-10-19T17:31:44Z
dc.date.available2018-07-04T15:08:27Z
dc.date.created2012-10-19T17:31:44Z
dc.date.issued2008
dc.identifierJOURNAL OF CLINICAL ULTRASOUND, v.36, n.5, p.273-278, 2008
dc.identifier0091-2751
dc.identifierhttp://producao.usp.br/handle/BDPI/22361
dc.identifier10.1002/jcu.20430
dc.identifierhttp://dx.doi.org/10.1002/jcu.20430
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1619133
dc.description.abstractPurpose. To use 3-dimensional sonography (3DUS) to measure contralateral lung volume and evaluate the potential of this measurement to predict neonatal outcome in isolated congenital diaphragmatic hernia (CDH). Methods. Between January 2002 and December 2004, the contralateral lung volumes of 39 fetuses with isolated CDH were measured via 3DUS using rotational multiplanar imaging. The observed/expected contralateral fetal lung volume ratios (o/eContFLVR) were compared with the lung/head ratio (LHR), observed/expected total fetal lung volume ratio (o/e-TotFLVR), and postnatal outcome. Results. Contralateral lung volumes are less reduced than total lung volumes in CDH. The bias and precision of 3DUS in estimating contralateral lung volumes were 0.99 cm(3) and 1.11 cm(3), respectively, with absolute limits of agreement ranging from -1.19 cm(3) to + 3.17 cm(3). The o/e-ContFLVR was significantly lower in neonatal death cases (median, 0.49 cm(3); range, 0.22-0.99 cm(3)) than in survival cases (median, 0.58 cm(3); range, 0.42-0.92 cm(3) [p < 0.011). Overall accuracy of the o/e-ContFLVR, o/e-TotFLVR, and LHR in predicting neonatal death were 67.7% (21/31), 80.7% (25/31), and 77.4% (24/31), respectively. Conclusion. Although o/e-ContFLVR can be precisely measured with 3DUS and can be used to predict neonatal death in CDH, it is less accurate than LHR and o/e-TotFLVR for that purpose. (C) 2007 Wiley Periodicals, Inc.
dc.languageeng
dc.publisherJOHN WILEY & SONS INC
dc.relationJournal of Clinical Ultrasound
dc.rightsCopyright JOHN WILEY & SONS INC
dc.rightsrestrictedAccess
dc.subject3-dimensional ultrasonography
dc.subjectcongenital diaphragmatic hernia
dc.subjectpulmonary hypoplasia
dc.subjectprenatal diagnosis
dc.subjectultrasonography
dc.subjectfetal malformations
dc.titleThree-dimensional sonographic measurement of contralateral lung volume in fetuses with isolated congenital diaphragmatic hernia
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución