dc.creatorOLIVEIRA, Edward Jose de
dc.creatorKANAMURA, HerminiaYohko
dc.creatorKioko Takei
dc.creatorHIRATA, Rosario Dominguez Crespo
dc.creatorVALLI, Luiz Carlos Pedrosa
dc.creatorNGUYEN, Nga Yen
dc.creatorRODRIGUES, Izabel de Carvalho
dc.creatorJESUS, Amelia Ribeiro de
dc.creatorHIRATA, Mario Hiroyuki
dc.date.accessioned2012-10-19T03:16:28Z
dc.date.accessioned2018-07-04T14:55:25Z
dc.date.available2012-10-19T03:16:28Z
dc.date.available2018-07-04T14:55:25Z
dc.date.created2012-10-19T03:16:28Z
dc.date.issued2008
dc.identifierTRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, v.102, n.4, p.360-366, 2008
dc.identifier0035-9203
dc.identifierhttp://producao.usp.br/handle/BDPI/19547
dc.identifier10.1016/j.trstmh.2007.11.008
dc.identifierhttp://dx.doi.org/10.1016/j.trstmh.2007.11.008
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1616334
dc.description.abstractA pool of five synthetic peptides was used as an antigenic base in an ELISA (ELISA-Pp) for laboratory diagnosis of Schistosoma mansoni. Serum samples were obtained from individuals with acute (n = 23) and chronic (n = 30) schistosomiasis, with other parasitoses (n = 39) or without parasitic infections (n = 100). ELISA-Pp was compared with other immunoenzymatic methods for detection of IgM (IgM-ELISA) or IgG (IgG-ELISA) as well as an immunofluorescence test for detection of IgM antibodies (IgM-IFT). The sensitivity and specificity of ELISA-Pp was 86.8% and 94.2% when tested on the schistosomiasis group and the non-schistosomiasis group, respectively. Comparison of ELISA-Pp with other serological methods resulted in K concordance indices varying from 0.59 to 0.75. Evaluation of anti-peptide IgG antibodies showed higher Levels in patients with acute compared with chronic schistosomiasis (P = 0.001). ELISA-Pp showed satisfactory sensitivity and high specificity and may constitute a potentially useful method for laboratory diagnosis of schistosomiasis mansoni. (c) 2007 Royal Society of Tropical Medicine and Hygiene. Published by Elsevier Ltd. All rights reserved.
dc.languageeng
dc.publisherELSEVIER SCIENCE INC
dc.relationTransactions of the Royal Society of Tropical Medicine and Hygiene
dc.rightsCopyright ELSEVIER SCIENCE INC
dc.rightsclosedAccess
dc.subjectSchistosoma mansoni
dc.subjectdiagnosis
dc.subjectSeroLogy
dc.subjectELISA
dc.subjectsynthetic peptides
dc.subjectsensitivity and specificity
dc.titleSynthetic peptides as an antigenic base in an ELISA for laboratory diagnosts of schistosomiasis mansoni
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución