dc.creatorRibatski, Gherhardt
dc.creatorJabardo, Jose Maria Saiz
dc.creatorSILVA, Evandro Fockink da
dc.date.accessioned2012-10-19T01:13:01Z
dc.date.accessioned2018-07-04T14:49:12Z
dc.date.available2012-10-19T01:13:01Z
dc.date.available2018-07-04T14:49:12Z
dc.date.created2012-10-19T01:13:01Z
dc.date.issued2008
dc.identifierEXPERIMENTAL THERMAL AND FLUID SCIENCE, v.32, n.8, p.1530-1537, 2008
dc.identifier0894-1777
dc.identifierhttp://producao.usp.br/handle/BDPI/18092
dc.identifier10.1016/j.expthermflusci.2008.04.008
dc.identifierhttp://dx.doi.org/10.1016/j.expthermflusci.2008.04.008
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1614888
dc.description.abstractAn investigation of nucleate boiling on a vertical array of horizontal plain tubes is presented in this paper. Experiments were performed with refrigerant RI 23 at reduced pressures varying from 0.022 to 0.64, tube pitch to diameter ratios of 1.32, 1.53 and 2.00, and heat fluxes from 0.5 to 40 kW/m(2). Brass tubes with external diameters of 19.05 mm and average roughness of 0.12 mu m were used in the experiments. The effect of the tube spacing on the local heat transfer coefficient along the tube array was negligible within the present range of experimental conditions. For partial nucleate boiling, characterized by low heat fluxes, and low reduced pressures, the tube positioning shows a remarkable effect on the heat transfer coefficient. Based on these data, a general correlation for the prediction of the nucleate boiling heat transfer coefficient on a vertical array of horizontal tubes under flooded conditions was proposed. According to this correlation, the ratio between the heat transfer coefficients of a given tube and the lowest tube in the array depends only on the tube row number, the reduced pressure and the heat flux. By using the proposed correlation, most of the experimental heat transfer coefficients obtained in the present study were predicted within +/- 15%. The new correlation compares reasonably well with independent data from the literature. (C) 2008 Elsevier Inc. All rights reserved.
dc.languageeng
dc.publisherELSEVIER SCIENCE INC
dc.relationExperimental Thermal and Fluid Science
dc.rightsCopyright ELSEVIER SCIENCE INC
dc.rightsrestrictedAccess
dc.subjectnucleate boiling
dc.subjecttube bundle
dc.subjecthalocarbon refrigerant
dc.titleModeling and experimental study of nucleate boiling on a vertical array of horizontal plain tubes
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución