dc.creatorABREU, Marcos Felipe Marcatto de
dc.creatorGOBBI, Riccardo Gomes
dc.creatorZENAIDE, Maurício Rodrigues
dc.creatorCAMPOS, Gustavo Constantino de
dc.creatorPEREIRA, César Augusto Martins
dc.creatorPÉCORA, José Ricardo
dc.creatorCAMANHO, Gilberto Luis
dc.date.accessioned2012-03-26T18:40:56Z
dc.date.accessioned2018-07-04T14:16:06Z
dc.date.available2012-03-26T18:40:56Z
dc.date.available2018-07-04T14:16:06Z
dc.date.created2012-03-26T18:40:56Z
dc.date.issued2009
dc.identifierActa Ortopédica Brasileira, v.17, n.3, p.162-166, 2009
dc.identifier1413-7852
dc.identifierhttp://producao.usp.br/handle/BDPI/9845
dc.identifier10.1590/S1413-78522009000300008
dc.identifierhttp://www.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522009000300008
dc.identifierhttp://www.scielo.br/pdf/aob/v17n3/a08v17n3.pdf
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1607774
dc.description.abstractOBJETIVO: O cimento acrílico é utilizado há anos nas cirurgias ortopédicas, especialmente nas artroplastias do joelho, merecendo atenção também quando utilizado com o acréscimo de antibióticos (para tratamento de infecções) ou corantes (para facilitação de uma possível retirada). Neste estudo procurou-se avaliar diferenças mecânicas entre o cimento ortopédico puro e quando misturado com antibiótico e/ou corante. MÉTODOS: Foram utilizados cimento acrílico ortopédico Surgical Simplex®P Stryker, vancomicina em pó e azul de metileno e as misturas submetidas a testes físicos e mecânicos de acordo com a norma ABNT NBR ISO 5833. Avaliou-se: tempo para a formação de massa, capacidade de intrusão, resistência à compressão, resistência ao dobramento (tensão) e temperatura máxima atingida pelas misturas. RESULTADOS: As misturas avaliadas foram aprovadas quanto ao tempo de preparação da mistura, temperatura máxima alcançada, profundidade da intrusão e resistência à compressão. Somente aquela contendo apenas cimento puro foi aprovada no ensaio de flexão. CONCLUSÃO: O acréscimo de vancomicina e/ou azul de metileno ao cimento ortopédico Surgical Simplex®P Stryker reduz a resistência da mistura à flexão, sendo reprovada pela norma ABNT NBR ISO 5833.
dc.description.abstractOBJECTIVE: Acrylic cement has been used for years on orthopaedic surgeries, especially on knee arthroplasties, deserving special attention when added to antibiotics (for treatment of deep bone infections) or stains (to facilitate its removal). The present study was conducted in order to evaluate potential mechanical differences between the orthopaedic cement itself and when this is added to antibiotic and/or stains. METHODS: Surgical bone cement Simplex®P Stryker, vancomycin and methylene blue were used, and the mixtures were submitted to physical and mechanical tests according the ABNT NBR ISO 5833 rule. The parameters studied here were: time for mass formation, intrusion capability, resistance to compression, resistance to flexion and maximum temperature reached by the mixtures. RESULTS: The evaluated mixtures were approved as to mass formation, maximum temperature, intrusion capability and resistance to compression. Only the one containing pure cement was approved on the flexion essay. CONCLUSION: The addition of vancomycin and/or methylene blue to Surgical Simplex®P Stryker bone cement reduces its resistance to flexion, being unacceptable by the ABNT NBR ISO 5833 rule.
dc.languagepor
dc.publisherAtha Comunicação & Editora
dc.relationActa Ortopédica Brasileira
dc.rightsCopyright Atha Comunicação & Editora
dc.rightsopenAccess
dc.subjectCimentos para osso
dc.subjectPolimetilmetacrilato
dc.subjectArtroplastia
dc.subjectBone cements
dc.subjectPolymethylmetacrylate
dc.subjectArthroplasty
dc.titleAvaliação biomecânica do cimento ortopédico combinado com antibiótico e azul de metileno
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución