dc.creatorBITTAR, Roberto Eduardo
dc.creatorZUGAIB, Marcelo
dc.date.accessioned2012-03-26T18:27:27Z
dc.date.accessioned2018-07-04T14:12:59Z
dc.date.available2012-03-26T18:27:27Z
dc.date.available2018-07-04T14:12:59Z
dc.date.created2012-03-26T18:27:27Z
dc.date.issued2009
dc.identifierRevista Brasileira de Ginecologia e Obstetrícia, v.31, n.4, p.203-209, 2009
dc.identifier0100-7203
dc.identifierhttp://producao.usp.br/handle/BDPI/9322
dc.identifier10.1590/S0100-72032009000400008
dc.identifierhttp://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-72032009000400008
dc.identifierhttp://www.scielo.br/pdf/rbgo/v31n4/08.pdf
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1607330
dc.description.abstractEntre os vários fatores clínicos para o parto prematuro, alguns apresentam riscos substanciais, tais como história de parto prematuro, gemelidade e sangramento vaginal do segundo trimestre. No entanto, tais fatores estão presentes na minoria das mulheres que evoluem para o parto prematuro e, portanto, possuem baixa sensibilidade. A dilatação, o esvaecimento e a posição do colo uterino diagnosticados pelo toque vaginal têm sido relacionados ao aumento do risco para o parto prematuro, mas possuem baixas sensibilidades e baixos valores preditivos positivos. A diminuição do comprimento do colo uterino detectada pela ultrassonografia transvaginal também constitui risco para parto prematuro. Sua sensibilidade é melhor quando são considerados outros testes, mas o valor preditivo positivo é baixo. A principal utilidade do teste da fibronectina fetal reside em seu valor preditivo negativo em mulheres sintomáticas. Observa-se aumento da sensibilidade para a detecção do parto prematuro quando a medida do colo do útero é utilizada juntamente com o teste da fibronectina fetal.
dc.description.abstractAmong the clinical factors for preterm birth, some confer substantial increased risk, including a history of preterm birth, multiple gestation and vaginal bleeding in the second trimester. However, these factors are present only in a minority of women who ultimately deliver preterm and thus have low sensitivity. Cervical dilatation, effacement and position as determined by manual examination have been related to an increased risk of preterm birth but also suffer from low sensitivity and positive predictive values. Cervical length measured with transvaginal ultrasound has also been related to an increased risk of preterm birth as cervical length decreases. The reported sensitivity is better than other tests, but positive predictive value is low. The principal utility of the fetal fibronectin assay lies in its negative predictive value in symptomatic women. Increased sensitivity has been reported when cervical length is used in combination with fetal fibronectin.
dc.languagepor
dc.publisherFederação Brasileira das Sociedades de Ginecologia e Obstetrícia
dc.relationRevista Brasileira de Ginecologia e Obstetrícia
dc.rightsCopyright Federação Brasileira das Sociedades de Ginecologia e Obstetrícia
dc.rightsopenAccess
dc.subjectFatores de risco
dc.subjectColo do útero - ultra-sonografia
dc.subjectFibronectinas - análise
dc.subjectTrabalho de parto prematuro - prevenção & controle
dc.subjectValor preditivo dos testes
dc.subjectMedição de risco
dc.subjectSensibilidade e especificidade
dc.subjectRisk factors
dc.subjectCervix uteri - ultrassonography
dc.subjectFibronectins - analysis
dc.subjectObstetric labor, premature - prevention & control
dc.subjectPredictive value of tests
dc.subjectRisk assessment
dc.subjectSensitivity and specificity
dc.titleIndicadores de risco para o parto prematuro
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución