dc.creatorNascimento, Eduardo Marcel Fernandes
dc.creatorLima-Silva, Adriano Eduardo
dc.creatorBertuzzi, Rômulo Cássio de Moraes
dc.creatorKiss, Maria Augusta Peduti Dal Molin
dc.creatorPires, Flavio de Oliveira
dc.date.accessioned2012-03-26T00:16:44Z
dc.date.accessioned2018-07-04T13:48:30Z
dc.date.available2012-03-26T00:16:44Z
dc.date.available2018-07-04T13:48:30Z
dc.date.created2012-03-26T00:16:44Z
dc.date.issued2011
dc.identifierRevista Brasileira de Cineantropometria & Desempenho Humano (Online), v.13, n.4, p.285-291, 2011
dc.identifier1980-0037
dc.identifierhttp://producao.usp.br/handle/BDPI/2842
dc.identifier10.5007/1980-0037.2011v13n4p285
dc.identifierhttp://www.scielo.br/scielo.php?script=sci_arttext&pid=S1980-00372011000400007
dc.identifierhttp://www.scielo.br/pdf/rbcdh/v13n4/07.pdf
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1602009
dc.description.abstractO propósito deste estudo foi analisar o comportamento da frequência cardíaca (FC) versus a carga de trabalho crescente (CTC) em teste de esteira, utilizando três modelos matemáticos (linear, linear com dois segmentos de reta e sigmóide) e verificar qual o melhor modelo que possibilita a identificação de um limiar de FC que pudesse servir de preditor para os limiares ventilatórios (LV1 e LV2). Vinte e dois homens realizaram um teste incremental (re-teste: n=12), com velocidade inicial de 5,5 km.h-1 e incrementos de 0,5 km.h-1 a cada minuto, até a exaustão. Medidas contínuas de FC e trocas gasosas foram convertidas para médias de 5 e 20 segundos. Somatória dos resíduos quadrados e quadrado médio do erro foram usados para verificar o melhor ajuste. A relação FC/CTC foi melhor representada pelo modelo Lin2 no grupo teste e re-teste (p<0,05). Foi possível identificar um ponto de deflexão de FC, utilizando o modelo Lin2 (limiar de FC) em todos os indivíduos no teste (164 ± 16,6 bpm; 83,6% FC MÁX) e no re-teste (162 ± 20,0 bpm; 83,9% FC MÁX). O limiar de FC (Lin2PDFC) ocorreu a 9,2 ± 1,3 km.h-1 (67,9% VelMÁX) e foi menor que o LV2 (LV2= 10,6 ± 1,5 km.h-1; 77,3% VelMÁX; p< 0,05), mas não diferente de LV1 (8,4 ± 1,2 km.h-1; 61,6% VelMÁX; p&gt; 0,05). Durante teste incremental em esteira, a relação FC/CTC parece ser bem descrita por uma função linear com 2 segmentos de reta, a qual permite a determinação de um limiar de FC que se aproxima do LV1.
dc.description.abstractThe objective of this study was to analyze the heart rate (HR) profile plotted against incremental workloads (IWL) during a treadmill test using three mathematical models [linear, linear with 2 segments (Lin2), and sigmoidal], and to determine the best model for the identification of the HR threshold that could be used as a predictor of ventilatory thresholds (VT1 and VT2). Twenty-two men underwent a treadmill incremental test (retest group: n=12) at an initial speed of 5.5 km.h-1, with increments of 0.5 km.h-1 at 1-min intervals until exhaustion. HR and gas exchange were continuously measured and subsequently converted to 5-s and 20-s averages, respectively. The best model was chosen based on residual sum of squares and mean square error. The HR/IWL ratio was better fitted with the Lin2 model in the test and retest groups (p<0.05). The Lin2 model permitted the identification of the HR threshold (Lin2HRDP) in all subjects of the test (164 ± 16.6 bpm; 83.6% HR MAX) and retest groups (162 ± 20.0 bpm; 83.9% HR MAX). Lin2HRDP (9.2 ± 1.3 km.h-1; 67.9% speedMAX) was lower than VT2 (10.6 ± 1.5 km.h-1, 77.3% speedMAX; p<0.05), but did not differ from VT1 (8.4 ± 1.2 km.h-1, 61.6% speedMAX; p&gt;0.05). During a treadmill incremental test, the HR/IWL ratio seems to be better fitted with a Lin2 model, which permits to determine the HR threshold that coincides with VT1.
dc.languagepor
dc.publisherUniversidade Federal de Santa Catarina
dc.relationRevista Brasileira de Cineantropometria & Desempenho Humano (Online)
dc.rightsCopyright Universidade Federal de Santa Catarina
dc.rightsopenAccess
dc.subjectAjuste sigmóide de Boltzmann
dc.subjectErgometria
dc.subjectTeste de esteira rolante
dc.subjectEsforço físico
dc.subjectFrequência cardíaca
dc.subjectBoltzmann sigmoidal model
dc.subjectErgometry
dc.subjectExercise test
dc.subjectPhysical exertion
dc.subjectHeart rate
dc.titleCaracterização da curva da frequência cardíaca durante teste incremental máximo em esteira
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución