dc.contributorVisitación Figueroa, Lizardo
dc.creatorCallo Aguirre, Natalie Liv
dc.creatorLaura Vigo, Martha Elena
dc.date2017-01-13T16:21:36Z
dc.date2017-01-13T16:21:36Z
dc.date2014
dc.date.accessioned2018-04-02T19:40:43Z
dc.date.available2018-04-02T19:40:43Z
dc.identifierT01.C34-T BAN UNALM
dc.identifierhttp://repositorio.lamolina.edu.pe/handle/UNALM/2433
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1369850
dc.descriptionCiclo Optativo de Especialización y Profesionalización en Gestión de Calidad y Auditoría Ambiental
dc.descriptionEl diseño de un vertimiento puede influir en la velocidad de mezcla del efluente con el cuerpo receptor, y por lo tanto, en la autodepuración de este último. El efluente minero, objeto de estudio, corresponde a un botadero de desmonte ubicado en el departamento del Cusco, donde se almacena material con baja ley proveniente de una Unidad Minera a tajo abierto de explotación y beneficio de oro y plata. El efluente minero en mención es vertido en la quebrada Chonta; como producto de la infiltración de la precipitación, en el área expuesta del botadero, se caracteriza por su bajo pH y elevado contenido de metales disueltos. Pese a que este efluente pasa por un sistema de tratamiento, previo a su vertimiento en el cuerpo receptor, el objetivo de la presente investigación es proponer una mejora del diseño de dicho vertimiento y favorecer la autodepuración de la quebrada. En primer lugar, se realizó un procesamiento de datos con base en los informes de monitoreo trimestrales del mencionado efluente y cuerpo receptor, para luego hacer un diagnóstico de la situación real del cuerpo receptor y del efluente. Posteriormente, se analizó el comportamiento del efluente en el cuerpo receptor con la implementación de tres (03) mejoras técnicas, para después de comparar, elegir la mejora técnica óptima. Finalmente se calcularon y compararon los Índices de Calidad de Agua (ICA) en la quebrada Chonta, calculados para la situación real y la situación con la mejora técnica óptima. Cabe indicar que los resultados determinaron la mejora técnica óptima que consistía en una tubería sumergida en la quebrada, a una altura de 0.6 m del fondo de la misma. Además, las comparaciones de los ICA arrojaron que la calidad de la quebrada Chonta mejoraba en época húmeda, de Bueno a Excelente y de Marginal a Bueno, para los ECA Categoría 1A y 4, respectivamente.
dc.descriptionA shedding design might influence the mixing speed of the effluent and the receptor, but also in the cleaning of the latter. We evaluated a waste rock dump (mining effluent) produced by an open pit mining unit, which processes gold and silver, located in Cusco. As a result of infiltration and precipitation, this mining effluent is dragged to Chonta stream. Although this effluent is treated prior to its discharge into the receiving body, the area exposed to the mining effluent is characterized by low pH and high dissolved metals. The aim of this research is to propose an improved design of the dumping and promote self purification of the creek. We used the trimestral monitoring results of the effluent and the receptor and performed a data processing and made a diagnosis of the real situation of the receiving body and effluent. The behavior of the effluent in the receptor was analyzed with the implementation of three (03) technical improvements, later, the best technical improvement for such analysis was chosen. Finally, we calculated and compared the observed results and the results obtained from the technical improvements with the Water Quality Index (“Indices de Calidad de Agua” - ICA). The best technical improvement consisted in a pipe submerged in the creek, at a height of 0.6 m at the bottom. Further, comparisons of the ICA showed that the quality of Chonta stream improved in wet season, from Good to Great and Marginal Well, for RCTs Category 1A and 4, respectively
dc.descriptionTesis
dc.formatapplication/pdf
dc.languagespa
dc.publisherUniversidad Nacional Agraria La Molina
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceUniversidad Nacional Agraria La Molina
dc.sourceRepositorio institucional - UNALM
dc.subjectCusco (dpto)
dc.subjectChumbivilcas (prov)
dc.subjectQuiñota (dist)
dc.subjectCerro Huisamarca
dc.subjectQuebrada Chonta
dc.subjectModelo de dispersión contaminantes
dc.subjectVertimientos mineros
dc.subjectPerú
dc.subjectMinería
dc.subjectAguas residuales
dc.subjectPolución del agua
dc.subjectCalidad del agua
dc.subjectCarga contaminante
dc.subjectDiseño
dc.subjectModelos dinámicos
dc.subjectEfluentes
dc.subjectEvaluación
dc.subjectProgramas de ordenador
dc.titlePropuesta de mejoramiento de diseño del vertimiento de un efluente minero en la quebrada Chonta mediante la aplicación de un modelo de dispersión de contaminantes y los índices de calidad de agua
dc.typeTesis


Este ítem pertenece a la siguiente institución