Development of an analytical method for the determination of sunscreens using high permormance liquid chormatography and evaluation of the correlation between the suncreen protection factor measured in vivo and in vitro method by near infrared spectroscopy and chemometrics

dc.creatorNery, Daiane Camilo, 1981-
dc.date2016
dc.date2017-04-03T09:20:54Z
dc.date2017-10-16T13:00:54Z
dc.date2017-04-03T09:20:54Z
dc.date2017-10-16T13:00:54Z
dc.date.accessioned2018-03-29T05:36:44Z
dc.date.available2018-03-29T05:36:44Z
dc.identifierNERY, Daiane Camilo. Desenvolvimento de método para a determinação de filtros solares orgânicos por cromatografia líquida de alta eficiência e avaliação da correlação do fator de proteção solar medido in vivo e in vitro por espectroscopia no infravermelho próximo e quimiometria. 2016. 1 recurso online (114 p.). Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Química, Campinas, SP. Disponível em: <http://www.bibliotecadigital.unicamp.br/document/?code=000972210>. Acesso em: 3 abr. 2017.
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/305771
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1360580
dc.descriptionOrientadores: Susanne Rath, Jarbas José Rodrigues Rohwedder
dc.descriptionDissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Química
dc.descriptionResumo: O objetivo desse trabalho foi propor uma técnica alternativa aos testes in vivo para a determinação do Fator de Proteção Solar (FPS) em protetores solares utilizando as técnicas de espectroscopia NIR associada à quimiometria e a cromatografia líquida de alta eficiência com detetor de arranjo de fotodiodos (HPLC-DAD). Para o desenvolvimento e validação do método cromatográfico, selecionaram-se dez compostos presentes nos principais protetores solares comercializados no Brasil: benzofenona-3, octocrileno, octildimetilpaba, metoxicinamato de octila, avobenzona, homosalato, salicilato de octila, etilexiltriazona, Tinosorb M e Tinosorb S. O método otimizado para separação dos compostos utilizou uma coluna cromatográfica ACE C18 (150 mm x 4.6 mm, 3 ?m) mantida na temperatura de 30 °C e fase móvel composta por metanol:água:tetraidrofurano com eluição por gradiente. A vazão foi de 0,85 mL min-1 e o tempo de corrida foi de 17 minutos. A avobenzona foi quantificada no comprimento de onda de 358 nm e os demais compostos em 310 nm. Para determinação do teor dos compostos nas formulações foi utilizado método de padronização externa, exceto para o composto etilexiltriazona que foi avaliado pelo método de adição de padrão. Para avaliar o emprego da espectroscopia NIR na previsão do FPS de protetores solares, dois modelos quimiométricos de calibração PLS (Partial Least Squares) foram construídos: um modelo para previsão do FPS e outro para previsão das concentrações de alguns dos compostos ativos presentes nos produtos. O conjunto de amostras utilizado foi composto de amostras disponibilizadas pela empresa Allergisa, provenientes de um estudo de FPS in vivo, e também pela seleção de amostras comerciais. Através dos espectros obtidos e dos valores de referência do FPS foi possível construir um modelo de previsão do FPS dos produtos e com os valores de concentração de algumas substâncias ativas determinadas por HPLC-DAD
dc.descriptionAbstract: The aim of this work was to propose an alternative technique to in vivo tests to determine the Sun Protection Factor (SPF) in sunscreen lotions using NIR spectroscopy associated to chemometric methods and high performance liquid chromatography with photodiode arrady detection. For the development and validation of the chromatographic method, ten active ingredients used in the main sunscreens commercialized in Brazil were selected: benzophenone 3, octocrylene, octyldimethylpaba, octyl methoxycinnamate, avobenzone, homosalate, octyl salicylate, ethylhexyl triazone, Tinosorb M and Tinosorb S. The compounds were separated using an ACE C18 (150 mm x 4.6 mm, 3 ?m) chromatographic column operating at 30 °C; methanol:water:tetrahydrofurane under a gradient elution was used as mobile phase. The flow rate was 0.85 mL min-1 and the run time 17 minutes. Whereas avobenzone was quantified at 358 nm the other compounds were measured at 310 nm. The determination of the concentration of the active ingredients in the sun lotions was done using an external standard calibration method, except for ethylhexyl triazone that was evaluated by the standard addition method. To evaluate the use of NIR spectroscopy for the prediction of the SPF in sun lotions, two chemometric calibration models (Partial Least Squares) were constructed: a model to predict the SPF in the samples and another to predict the concentration of some of the active substances in the products. The set of samples used for the calibration was composed of samples provided by the company Allergisa, from an in vivo SPF determination test, and commercial samples. Through the NIR spectra and the reference SPF values it was possible to build a SPF prediction model and with the concentration of the active substances determined by HPLC
dc.descriptionMestrado
dc.descriptionQuimica Analitica
dc.descriptionMestra em Química
dc.format1 recurso online (114 p.) : il., digital, arquivo PDF.
dc.formatapplication/pdf
dc.publisher[s.n.]
dc.relationRequisitos do sistema: Software para leitura de arquivo em PDF
dc.subjectFator de proteção solar
dc.subjectCromatografia líquida de alta eficiência
dc.subjectInfravermelho próximo
dc.subjectSun protection factor
dc.subjectHigh performance liquid chromatography
dc.subjectNear infrared
dc.titleDesenvolvimento de método para a determinação de filtros solares orgânicos por cromatografia líquida de alta eficiência e avaliação da correlação do fator de proteção solar medido in vivo e in vitro por espectroscopia no infravermelho próximo e quimiometria
dc.titleDevelopment of an analytical method for the determination of sunscreens using high permormance liquid chormatography and evaluation of the correlation between the suncreen protection factor measured in vivo and in vitro method by near infrared spectroscopy and chemometrics
dc.typeTesis


Este ítem pertenece a la siguiente institución