Optimizing the capture and analysis of Hunter-Schreger bands for human identification

dc.creatorLopez Arrieta, Zulieth Del Carmen, 1988-
dc.date2016
dc.date2017-10-11T12:50:40Z
dc.date2017-10-11T12:50:40Z
dc.date.accessioned2018-03-29T05:34:02Z
dc.date.available2018-03-29T05:34:02Z
dc.identifierLOPEZ ARRIETA, Zulieth Del Carmen. Otimização da captura e análise das bandas de Hunter-Schreger para identificação humana = Optimizing the capture and analysis of Hunter-Schreger bands for human identification. 2016. 1 recurso online (42 p.). Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba, Piracicaba, SP. Disponível em: <http://www.repositorio.unicamp.br/handle/REPOSIP/305528>. Acesso em: 11 out. 2017.
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/305528
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1359913
dc.descriptionOrientador: Sergio Roberto Peres Line
dc.descriptionDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
dc.descriptionResumo: O padrão das bandas de Hunter-Schreger pode ser utilizado como método biométrico para a identificação pessoal, porém a falta de desenvolvimento técnico e padronização de protocolos dificulta o uso massivo desta ferramenta. O objetivo neste trabalho foi otimizar as condições para obtenção, processamento e análise das imagens das bandas de Hunter-Schreger. Os principais obstáculos para obtenção de uma imagem de boa qualidade das bandas de Hunter-Schreger são: 1) a superfície curva e vítrea do esmalte que fazem com que parte da luz incidente seja refletida, 2) a presença de trincas verticais que interrompem a continuidade dos prismas diminuindo a passagem da luz no interior do esmalte, 3) a dificuldade para capturar o padrão completo das bandas de Hunter-Schreger numa fotografia 4) a perda do foco por movimentos derivados de processos fisiológicos do indivíduo. Para reduzir a luz refletida foi testado o filtro polarizador e para diminuir a perda da luz devido à presença de trincas foi testado óleo de milho; foram fotografados 11 dentes com a câmera Canon EOS 5D adaptada a uma lupa estereoscópica com tempos de exposição de 1.3" e 2.0". O contraste foi mensurado com o software ImageJ em duas regiões: (1) próximo à área de brilho intenso, (2) após a trinca. Os dados foram analisados com o teste de Wilcoxon no software R. Os resultados mostraram que, com tempo de exposição 1,3" na região 1 e 2, o uso do filtro polarizador melhorou a observação das bandas de Hunter-Schreger (p<0,05) e o uso do óleo melhorou a visualização das bandas Hunter-Schreger após a trinca (p<0,05). O tempo de exposição 2.0", não mostrou diferenças significativas com uso de filtro polarizador (p>0,05), porém mostrou maior contraste das bandas com o uso de óleo (p<0,05). Para determinar o tempo ideal de exposição ao óleo de milho, 5 dentes foram fotografados após 0, 1, 10 e 30 minutos de exposição. O contraste foi mensurado com o software ImageJ. O teste ANOVA medidas repetidas (SPSS) mostrou que a exposição de 1 minuto é suficiente para o óleo conseguir penetrar na trinca (p<0,05). Para ampliar a área de visualização das bandas de Hunter-Schreger, foram obtidas duas fotografias de cada dente (teste In situ: N=5, teste In vivo: N=5) com deslocamento lateral da luz incidente, com a câmera Canon EOS 5S e objetiva Infinity probe TS 160 e depois contrastadas nos programas Corel PHOTO-PAINT ou Imagemagick. A áreas de interesse nas fotografias foram cortadas e somadas no programa Gimp e analisadas no programa Verifinger. O teste T pareado (R) mostrou um número maior de minúcias (p<0,05) nas imagens finais. O uso da câmera Canon EOS 5S e a lente Infinity objetivo Probe TS 160 facilitaram a captura In situ das bandas Hunter-Schreger sem perda do foco
dc.descriptionAbstract: The Hunter-Schreger bands can be used to efficient biometric personal identification system, however the lack of technical development and standardization of protocols hinders the massive use of this tool. The aim of this work was to optimize the conditions for obtaining, processing and analyses of Hunter-Schreger bands images. The main drawbacks to obtain a good quality Hunter-Schreger bands image are: 1) the reflection of a percentage of the incident light caused by the curve and vitreous enamel surface,.2) the interruption of the prisms integrity by vertical cracks, 3) difficulty to capture the full pattern of Hunter-Schreger bands in a photograph 4) loss of focus by derivatives of physiological processes from individual movements. In order, a polarizing filter was used to reduce the reflection and the corn oil was used to reduce the loss of the light; 11 teeth were photographed using Canon EOS 5D camera adapted to a stereoscopic microscope using 1.3" and 2.0" exposure times. The contrast was measured with ImageJ software in two regions: (1) close to the area of intense shine and (2) after the crack. Data were analyzed using Wilcoxon in R software. Results showed that exposure time 1.3" in the region 1 and region 2 the polarized filter with the minima absorptions improved observation of Hunter-Schreger bands; the use of oil improved the visualization of Hunter-Schreger bands after the crack (p<0.05). The exposure time 2.0", showed no significant differences with polarizing filter (p>0.05), nevertheless greater contrast of the bands with the use of oil (p<0.05). To determine the optimal exposure time to corn oil, 5 teeth were photographed after 0, 1, 10 and 30 minutes of exposition. The contrast was measured with ImageJ software. ANOVA one way with repeated measures test (SPSS) showed that 1 minute exposure is sufficient for oil to penetrate the crack (p<0.05). To increase Hunter-Schreger bands viewing area were obtained two photographs of each tooth (test In situ: N=5, test In vivo: N=5) with lateral displacement of the incident light using Canon EOS 5S and objective probe TS Infinity 160. The images were contrasted in Corel PHOTO-PAINT or Imagemagick software. Areas of interest in the photographs were cut and added in Gimp. T-Test for paired samples (R) showed a highest number of minutiae (p<0.05) in the final images. The using Canon EOS 5S camera and objective Infinity Probe TS 160 facilitated the capture In situ of Hunter-Schreger bands without loss of focus
dc.descriptionMestrado
dc.descriptionHistologia e Embriologia
dc.descriptionMestra em Biologia Buco-Dental
dc.description33003033001P3
dc.description2014/07112-1
dc.descriptionCAPES
dc.descriptionFAPESP
dc.format1 recurso online (42 p.) : il., digital, arquivo PDF.
dc.formatapplication/pdf
dc.languageInglês
dc.publisher[s.n.]
dc.relationRequisitos do sistema: Software para leitura de arquivo em PDF
dc.subjectOdontologia legal
dc.subjectIdentificação biométrica
dc.subjectEsmalte dentário
dc.subjectForensic dentistry
dc.subjectBiometric identification
dc.subjectDental enamel
dc.titleOtimização da captura e análise das bandas de Hunter-Schreger para identificação humana = Optimizing the capture and analysis of Hunter-Schreger bands for human identification
dc.titleOptimizing the capture and analysis of Hunter-Schreger bands for human identification
dc.typeTesis


Este ítem pertenece a la siguiente institución