Accuracy Of Partially Edentulous Arch Impressions Obtained From Different Alginates And Storage Times

dc.creatorMarcus Vinicius Loureiro Bertolo
dc.creatorMarcus Vinicius Loureiro Bertolo
dc.creatorLucas de Oliveira Tomaselli
dc.creatorGabriel Abuna
dc.date2016
dc.date2017-09-12T14:31:43Z
dc.date2017-09-12T14:31:43Z
dc.date.accessioned2018-03-29T05:32:07Z
dc.date.available2018-03-29T05:32:07Z
dc.identifierBrazilian Journal of Oral Sciences, v. 15, n. 4
dc.identifier1677-3225
dc.identifier10.20396/bjos.v15i4.8650031
dc.identifierhttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8650031
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/325226
dc.identifier8650031
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1359456
dc.descriptionThis study aimed to assess the dimensional accuracy of five commercial alginates verified in stone casts. Methods: Each alginate impression (Cavex ColorChange, Cavex Holland BV; Jeltrate Plus, Dentsply; Hydrogum, Zhermack; Kromopan 100, Lascod; Ezact Kromm, Vigodent) was performed on partially edentulous standard stainless steel mandibular arch cast with reference points on teeth 33, 43, 37 and 47. On the stainless steel cast, the anteroposterior (33-37 and 43-47) and transverse (33-43 and 37-47) distances were measured in a stereomicroscope at 30x magnification and 0.5 ?m accuracy. The distances between these points were measured three times, obtaining an average, which was analyzed statistically and compared with the distances obtained from the stone casts. For each alginate the casts were poured gypsum (n = 5) immediately and after a period of 1, 2, 3 and 5 days of the impression procedure. Results: The dimensional accuracy values of stone and stainless steel casts were analyzed statistically by two-way ANOVA and Tukey's test (?=0.05). The results showed significant differences between the alginates; however, no differences in dimensional accuracy were found among the different storage times of alginate impression. Conclusions: It can be concluded that the alginate impressions can be stored for up to 5 days.
dc.description15
dc.description4
dc.relationBrazilian Journal of Oral Sciences
dc.relationbjos
dc.rightsaberto
dc.sourcePPEC
dc.subjectDimensional Measurement Accuracy
dc.subjectDental Impression Material
dc.subjectMandibular Prosthesis
dc.titleAccuracy Of Partially Edentulous Arch Impressions Obtained From Different Alginates And Storage Times
dc.titleAccuracy Of Partially Edentulous Arch Impressions Obtained From Different Alginates And Storage Times
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución