Effect of implant length on stress induced by overdentures with single implant in photoelastic models

dc.creatorOliveira, Giovana Maria Camilo de, 1992-
dc.date2017
dc.date2017-02-17T00:00:00Z
dc.date2017-08-02T14:20:51Z
dc.date2017-08-02T14:20:51Z
dc.date.accessioned2018-03-29T05:13:18Z
dc.date.available2018-03-29T05:13:18Z
dc.identifierOLIVEIRA, Giovana Maria Camilo de. Efeito do comprimento do implante na tensão induzida por overdentures com um implante em modelos fotoelásticos. 2017. 1 recurso online ( 62 p.). Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba, Piracicaba, SP.
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/322720
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1356747
dc.descriptionOrientador: Rafael Leonardo Xediek Consani
dc.descriptionDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba
dc.descriptionResumo: O objetivo neste estudo foi verificar as tensões induzidas por overdentures com um implante com diferentes comprimentos (7, 9 e 11 mm) em modelos fotoelásticos mandibulares de Classe II, submetidas ao carregamento axial. Foi obtida uma matriz em gesso com formato mandibular com altura de 13 mm, com um orifício na linha mediana para colocação do análogo do implante. Por meio de moldagem para transferência da matriz foram obtidos moldes em silicone, onde foram parafusados os implantes e vertida a resina fotoelástica para obtenção dos modelos fotoelásticos para os grupos A, B e C (n=3). Nos modelos da matriz de gesso foram confeccionadas próteses totais convencionais superior e inferior pelo método tradicional e posteriormente foi realizada captura do o¿ring mandibular pela técnica direta. Para análise fotoelástica foi utilizada a técnica de transmissão plana, com polariscópio circular (PTH-A-01/LPM-UFU-MG) acoplado a uma câmera digital que gerou imagens para a análise qualitativa. Nos grupos A e B observou-se tensões concentradas no ápice do implante e região basal do modelo, sendo que no grupo A ocorreu maior concentração de tensão. No grupo C, as tensões estão concentradas no ápice do implante, região basal do modelo e na região cervical do implante. Em todos os grupos houve aumento da intensidade das franjas conforme a carga axial aumentou. Concluiu-se que a tensão se concentrou predominantemente ao redor do ápice do implante, qualquer que fosse o comprimento; quanto maior o comprimento do implante, menor a concentração da tensão; e quanto maior a carga axial, maior a concentração de tensões
dc.descriptionAbstract: The aim of this study was to verify the stress induced by overdentures with one implant with different lengths (7, 9 and 11 mm) in Class II mandibular photoelastic models submitted to axial loading. A mandibular stone matrix with 13 mm height was obtained, with a hole in the median line for placement of the implant analogue. By means of a matrix transfer molding, silicone molds were obtained, where the implants were screwed and the photoelastic resin was poured in order to obtain the photoelastic models for the groups A, B and C (n = 3). Plaster cast were made for maxillary and mandibular conventional complete prostheses by the traditional method, and after the mandibular o'ring was captured by the direct technique. In the photoelastic analysis was utilized the plan transmission technique with circular polariscope (PTH-A-01/LPM-UFU-MG) with a digital câmera attached. In the groups A and B there are concentrated tensions at the apical border of the implant and basal region of the model, with the group A showing a higher concentration of tension. In the group C the stresses concentrated at the apical border of the implant, basal region of the model and at the cervical region of the implant. In all groups there was increase in the fringes intensity as the axial load increased. In conclusion, the tension was concentrated predominantly around the apical edge of the implants, whatever the implant length; as longer as the implant length, lower the stress concentration; and as higher as the axial loading, higher stress concentration was observed
dc.descriptionMestrado
dc.descriptionProtese Dental
dc.descriptionMestra em Clínica Odontológica
dc.description33003033008P8
dc.descriptionCAPES
dc.format1 recurso online ( 62 p.) : il., digital, arquivo PDF.
dc.formatapplication/pdf
dc.publisher[s.n.]
dc.relationRequisitos do sistema: Software para leitura de arquivo em PDF
dc.subjectFotoelasticidade
dc.subjectRevestimento de dentadura
dc.subjectImplantes dentários
dc.subjectPhotoelasticity
dc.subjectOverlay dentures
dc.subjectDental implants
dc.titleEfeito do comprimento do implante na tensão induzida por overdentures com um implante em modelos fotoelásticos
dc.titleEffect of implant length on stress induced by overdentures with single implant in photoelastic models
dc.typeTesis


Este ítem pertenece a la siguiente institución