Use of small transverse incision technique for the treatment of carpal tunnel syndrome

dc.creatorKaleff, Paulo Roland, 1976-
dc.date2009
dc.date2017-03-30T17:33:12Z
dc.date2017-07-20T12:56:52Z
dc.date2017-03-30T17:33:12Z
dc.date2017-07-20T12:56:52Z
dc.date.accessioned2018-03-29T05:08:51Z
dc.date.available2018-03-29T05:08:51Z
dc.identifierKALEFF, Paulo Roland. Utilização de tecnica de incisão transversa minima no tratamento da sindrome do tunel do carpo. 2009. 76 f. Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas, Campinas, SP. Disponível em: <http://libdigi.unicamp.br/document/?code=000449753>. Acesso em: 30 mar. 2017.
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/308844
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1355683
dc.descriptionOrientador: Donizeti Cesar Honorato
dc.descriptionDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas
dc.descriptionResumo: Propósito:Avaliação de técnica de incisão transversa limitada no tratamento da síndrome do túnel do carpo, quanto à segurança cirúrgica e efetividade na abertura do Retináculo Flexor(RF). Método: Estudo prospectivo de Trinta procedimentos realizados em vinte e oito pacientes submetidos à técnica com incisão transversa mínima. A segurança da técnica e a abertura total do RF foram avaliadas através de questionário baseado em observações clinicas e inspeção endoscópica, respectivamente. Resultados: Não foram observadas complicações maiores. Um único paciente apresentou neuropraxia de N. interdigital. Dois pacientes apresentaram hematoma local pequeno. Em dois dos cinco primeiros casos, durante a inspeção endoscópica, observou-se abertura incompleta do RF, sendo necessária abertura complementar. Todos os pacientes apresentaram melhora do quadro clínico de dor noturna e parestesias. Conclusão: A técnica foi executada com segurança no grupo analisado, sem a ocorrência de complicações graves, e com abertura do RF na quase totalidade dos casos. Uma avaliação de longo prazo e com um número maior de pacientes é necessária.
dc.descriptionAbstract: Purpose: To evaluate the application of a limited transverse incision technique to treat the Carpal tunnel syndrome, with concern to its safety and efficacy in the opening of the Flexor Retinaculum (FR). Method: A prospective analysis of thirty FR release procedures performed on twenty-eight patients subjected to the proposed incision technique. Safety and total opening of the FR were evaluated through a questionnaire and an endoscopic inspection respectively. Results: No major complications were observed. Two cases presented small local hematoma. One patient presented with transient neuropraxia of digital branch. In two of the first five cases, incomplete FR opening was identified during endoscopic revision with need of complementary opening. All patients showed symptom relief. Conclusion: The technique was safely performed on the prospection group, no major complications were detected and the opening of FR was observed in the majority of the patients. Long term results and with a larger series of patients should be evaluated in further studies.
dc.descriptionMestrado
dc.descriptionNeurologia
dc.descriptionMestre em Ciências Médicas
dc.format76 f. : il.
dc.formatapplication/pdf
dc.languagePortuguês
dc.publisher[s.n.]
dc.subjectNervos perifericos
dc.subjectSíndrome do túnel carpal
dc.subjectCirurgia
dc.subjectProcedimentos cirúrgicos minimamente invasivos
dc.subjectPeripheral nerves
dc.subjectCarpal tunnel syndrome
dc.subjectSurgery
dc.subjectSurgical procedures, Minimally invasive
dc.titleUtilização de tecnica de incisão transversa minima no tratamento da sindrome do tunel do carpo
dc.titleUse of small transverse incision technique for the treatment of carpal tunnel syndrome
dc.typeTesis


Este ítem pertenece a la siguiente institución