Analysis of mandibular test specimens used to assess a bone fixation system

dc.creatorBaccarin, Leandro Stocco, 1978-
dc.date2013
dc.date2017-04-01T14:30:18Z
dc.date2017-07-20T12:55:26Z
dc.date2017-04-01T14:30:18Z
dc.date2017-07-20T12:55:26Z
dc.date.accessioned2018-03-29T05:07:50Z
dc.date.available2018-03-29T05:07:50Z
dc.identifierBACCARIN, Leandro Stocco. Análise de corpos de prova mandibulares utilizados para avaliação de sistema de fixação óssea = Analysis of mandibular test specimens used to assess a bone fixation system. 2013. 52 f. Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas, Campinas, SP. Disponível em: <http://www.bibliotecadigital.unicamp.br/document/?code=000901441>. Acesso em: 1 abr. 2017.
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/310497
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1355444
dc.descriptionOrientador: Luis Augusto Passeri
dc.descriptionDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas
dc.descriptionResumo: Objetivo: O objetivo deste trabalho é avaliar, por meio de testes biomecânicos, se materiais sintéticos diferentes, empregados para a confecção de corpos de prova apresentam comportamento biomecânico diferente, em comparação aos demais, ao simular in vitro a resistência ao carregamento de um método de fixação consagrado para OSRM. Material: 30 réplicas de hemimandíbulas humana, sintéticas e padronizadas, com OSRM, divididas em três grupos de 10 amostras cada: Grupo A - plástico ABS, Grupo B - Poliamida, e Grupo C - Poliuretano. Estas foram fixadas por três parafusos bicorticais posicionais (16 mm de comprimento, sistema 2.0 mm), em disposição "L" invertido, utilizando-se guias de perfuração e avanço de 5 mm. Métodos: Cada amostra foi submetida ao carregamento linear vertical e os valores de resistência ao carregamento registrado em 1, 3, 5, 7 e 10 mm de deslocamento. As médias e desvio padrão foram comparados, empregando-se análise de variância (p<0.05) e pelo teste Tukey. Resultados: Notou-se uma tendência de menores valores no grupo B em relação aos grupos A e C. Nos deslocamentos 3 e 5 mm, houve uma diferença entre os grupos A e C para o grupo B (p<0.05). Nos deslocamentos 7 e 10 mm houve diferença entre os 3 grupos sendo os maiores valores encontrados no grupo C e os menores no grupo B (p<0.05). Conclusões: Levando-se em consideração os resultados obtidos e o comportamento de cada material utilizado como substrato, podemos considerar que ocorreram diferenças significativas entre os materiais, quando comparados entre si
dc.descriptionAbstract: Purpose: The aim of this study was to assess through biomechanical testing if different synthetic materials used to fabricate test specimens have a different biomechanical behavior in comparison with other materials when simulating in vitro load resistance of a fixation method established for SSRO. Material: Thirty synthetic and standardized human hemimandible replicas with SSRO were divided into three groups of 10 samples each. Group A - ABS plastic; Group B - Polyamide and Group C - Polyurethane. These were fixated with three bicortical position screws (16 mm in length, 2.0mm system) in an inverted L pattern using perforation guide and 5 mm advancement. Methods: Each sample was submitted to linear vertical load and load strength values were recorded at 1, 3, 5, 7 and 10 mm of displacement. The means and standard deviation were compared using the Analysis of Variance (p<0.05) and the Tukey's test. Results: A tendency for lower values was observed in Group B in comparison with Groups A and C. At 3 and 5 mm of displacement, a difference between Groups A and C was found in comparison with Group B (p<0.05). At 7 and 10 mm of displacement a difference was found among the 3 groups, in which Group C showed the highest values and Group B the lowest (p<0.05). Conclusions: Taking into consideration the results obtained and the behavior of each material used as a substrate, significant differences occurred among the materials when compared among them
dc.descriptionMestrado
dc.descriptionFisiopatologia Cirúrgica
dc.descriptionMestre em Ciências
dc.format52 f. : il.
dc.formatapplication/pdf
dc.languagePortuguês
dc.publisher[s.n.]
dc.subjectBiomecânica
dc.subjectOsteotomia sagital do ramo mandibular
dc.subjectAvanço mandibular
dc.subjectBiomechanics
dc.subjectOsteotomy, Sagittal split ramus
dc.subjectMandibular advancement
dc.titleAnálise de corpos de prova mandibulares utilizados para avaliação de sistema de fixação óssea = Analysis of mandibular test specimens used to assess a bone fixation system
dc.titleAnalysis of mandibular test specimens used to assess a bone fixation system
dc.typeTesis


Este ítem pertenece a la siguiente institución