Epidemiology of mandibular fractures and mechanical evaluation of fixation methods of angle fractures in polyuretane mandibles

dc.creatorMuñante Cardenas, Jose Luis
dc.date2014
dc.date2017-04-02T05:43:10Z
dc.date2017-07-20T12:31:51Z
dc.date2017-04-02T05:43:10Z
dc.date2017-07-20T12:31:51Z
dc.date.accessioned2018-03-29T04:52:35Z
dc.date.available2018-03-29T04:52:35Z
dc.identifierMUÑANTE CARDENAS, Jose Luis. Epidemiologia das fraturas mandibulares e avaliação mecânica de métodos de fixação de fraturas de ângulo em mandíbulas de poliuretano. 2014. 91 f. Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas, Campinas, SP. Disponível em: <http://www.bibliotecadigital.unicamp.br/document/?code=000931819>. Acesso em: 2 abr. 2017.
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/312438
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1352015
dc.descriptionOrientador: Luis Augusto Passeri
dc.descriptionTexto em português e inglês
dc.descriptionTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas
dc.descriptionResumo: Este estudo teve como objetivo avaliar as características epidemiológicas de casos envolvendo fraturas mandibulares e o comportamento mecânico de quatro diferentes métodos de fixação de fraturas de ângulo mandibular. Foi realizado um levantamento epidemiológico sobre os casos de fraturas de mandíbula tratados pela Área de Cirurgia Plástica do Hospital das Clínicas da Universidade Estadual de Campinas (Unicamp). Foram analisados os prontuários de 119 pacientes tratados entre janeiro de 2006 e dezembro de 2011. As fraturas identificadas afetaram principalmente pacientes jovens do gênero masculino. Os acidentes de trânsito causaram o maior número de fraturas, sendo os acidentes de motocicleta a causa mais comum. As regiões mandibulares mais envolvidas foram a parassínfise e o ângulo. O tratamento cirúrgico foi aplicado na grande maioria dos casos. Complicações ocorreram em 36 pacientes (30,2%). As complicações no ângulo mandibular representaram 27% dos casos. A gravidade do trauma e a pouca colaboração dos pacientes foram fatores que contribuíram para o desenvolvimento de complicações pós-operatórias. Para a avaliação mecânica foram utilizadas quarenta réplicas de mandíbulas confeccionadas em poliuretano. As amostras foram divididas em quatro grupos com diferentes métodos de fixação: uma miniplaca, duas miniplacas dispostas paralelamente, uma miniplaca grade de 4 furos e uma miniplaca grade de 8 furos, todos do sistema de 2,0mm. Os grupos foram submetidos ao teste mecânico em uma máquina de ensaio universal, Instron 4411 (Instron Corp, Norwood, MA), recebendo uma carga vertical linear na região do incisivo e do primeiro molar. A técnica de duas placas paralelas apresentou resistência estatisticamente maior que todos os outros métodos de fixação. Entretanto, as placas grade de 4 furos não apresentaram diferença estatisticamente significante em relação ao grupo de uma miniplaca. As placas grade de 8 furos apresentaram os menores valores de resistência. Desta forma, a técnica de duas placas apresentou melhor comportamento mecânico para a fixação de fraturas de ângulo mandibular
dc.descriptionAbstract: The objectives of this study were evaluate the epidemiological characteristics of cases involving mandibular fractures and to evaluate the mechanical behavior of four different methods of fixation of fractures of the mandibular angle. An epidemiological survey on cases of mandibular fractures treated by the Department of Plastic Surgery, at the Clinical Hospital of University of Campinas, was performed. The medical records of 119 patients treated between January 2006 and December 2011 were analyzed. The fractures mainly affected young male patients. Road traffic accidents caused the largest number of fractures, being the motorcycle accidents the most common cause. The most affected regions were the mandibular angle and parasymphysis. Surgical treatment was applied in most cases. Complications occurred in 36 patients (30.2 %). Complications in mandibular angle accounted for 27 % of cases. The severity of the trauma and uncooperative patients were factors that contributed to the development of postoperative complications. To the mechanical evaluation, forty mandible replicas made of polyurethane were used. The samples were divided into four groups with different fixation methods: one miniplate, two parallel miniplates, a 3D miniplates with 4 holes and a 3D miniplate with 8 holes, all of them of a 2.0mm system. Each group was subjected to linear vertical loading at the incisal and molar region by an Instron 4411 mechanical testing unit (Instron Corp, Norwood, MA). The technique of two parallel miniplates showed statistically greater resistance than all other fixation methods. No statistically significant difference was observed in 3D miniplates with 4 holes in relation to the group of one miniplate. The 3DPP group showed lower values of strength. Thus, the technique of two miniplates showed better mechanical behavior for the fixation of the mandibular angle fractures
dc.descriptionDoutorado
dc.descriptionFisiopatologia Cirúrgica
dc.descriptionDoutor em Ciências
dc.format91 f. : il.
dc.formatapplication/pdf
dc.languageMultilíngua
dc.languageporeng
dc.publisher[s.n.]
dc.subjectFraturas mandibulares
dc.subjectEpidemiologia
dc.subjectMandibula
dc.subjectFraturas - Fixação
dc.subjectTraumatismos maxilofaciais
dc.subjectMandibular fractures
dc.subjectEpidemiology
dc.subjectMandible
dc.subjectFracture fixation
dc.subjectMaxillofacial injuries
dc.titleEpidemiologia das fraturas mandibulares e avaliação mecânica de métodos de fixação de fraturas de ângulo em mandíbulas de poliuretano
dc.titleEpidemiology of mandibular fractures and mechanical evaluation of fixation methods of angle fractures in polyuretane mandibles
dc.typeTesis


Este ítem pertenece a la siguiente institución